23
Connecting up
As a specialist, you alone are competent to
install and connect up ASKO appliances.
Our guarantee therefore applies only and
exclusively to appliances which have been
installed and connected up by you in
accordance with the provisions of current
regulations.
Failure to meet this requirement would
incur the fitter's liability and release the
ASKO company from any liability.
The electrical connections are made before
the oven is installed in its housing.
• The oven must be connected using an
approved 3-core cable (live, neutral and
earth) with 1.5 mm square conductors.
This should be connected via a 3- pin-
socket (live, neutral, and earth to the main
supply which should be should be a 220-
240V, alternating single-phase current.
If the oven is not connected using a plug
and socket, it must be connected to a
multi-pole switch with a minimum gap of
3 mm between contacts. The earth wire
(green and yellow) should be connected to
the terminal marked with the earth symbol
on the appliance and to the earth in the
switch.
• Where the oven is connected using a
separate plug and socket this must be
accessible after the oven has been
installed.
• The neutral wire (blue) of the oven must
be connected to the neutral in the main
supply.
• Tighten the clamp to hold the cable.
• Close the trapdoor using the two screws.
• The supply cable (H05 RR-F, H05 RN-F
or H05 W-F) must be long enough to allow
the oven to rest on the floor in front of its
housing.
With the oven sitting on the floor and
disconnected:
• Open the trapdoor at the bottom right
hand side at the back of the oven by
removing the 2 screws and swinging the
door away.
• Remove the sheath from each wire in the
new cable up to 12 mm.
• Twist the ends carefully together.
• Unscrew the terminal screws and remove
the wires that need changing.
• Pass the new cable through the wire
clamp to the right of the terminals.
• Connect the wires up in accordance with
the markings on the terminals.
• Make sure all wires are trapped under the
screws.
• The brown wire (live) going to terminal
marked L.
• The green and yellow wire (earth) going
to the one marked
.
• The blue wire (neutral) going to the
terminal marked N.
• Tighten the screws and check, by tugging
on each wire, that they are firmly
connected.
• Tighten the clamp to hold the cable.
• Close the trapdoor using the two screws.
Installer's information
Electricity meter (mains)
(20A, singlephase 220-240 V
alternating current 50 Hz)
Socket
2 -pin with earth
220-240 V single phase
alternating current supply
Connecting cable
approx 1.50 m. long
Fused 16A or
differential circuit breaker