7
DW70.5
1. Turn off the main power switch (I/0).
. Wait at least 5 seconds.
. Press and hold the Program and Start buttons
(S1 and S).
. Switch on the main power switch (I/0).
5. Release the Program and Start buttons (S1 and
S) when the LEDs have lit.
The most recent fault is shown in display D and D.
Error messages are erased by a total reset.
Press S1 to activate the component test. These are
activated in order after each button press and are
shown in display D.
1. Inlet valve and mixer valve (mixer valve open 1
second) then inlet valve open.
. Only inlet valve open.
. Salt water valve (salt and mixer valve only in
machines with water softener)
. Combi dispenser
5. Circulation pump
. Circ. pump and element (max. 75°C)
7. Fan and Vax motor
8. Drainage pump
Adjust water intake (in service menu)
Press the Program button (S1) for seconds to
activate the menu for setting the water intake.
Then use the Program button (S1) to step
through.
The display shows:
P:0 = Normal water intake volume
P:5 = Water intake volume increases by 5%
P:10 = Water intake volume increases by 10%
P:15 = Water intake volume increases by 15%
T:0 = Normal water intake volume
T:5 = Water intake volume increases by 5%
T:10 =Water intake volume increases by 10%
T:15 =Water intake volume increases by 15%
P = water intake controlled by flow meter
T = water intake time-controlled
Confirm selection by pressing Start (S). The
program returns to the main menu.
PROGRAMS AND CONTROl UNIT
Содержание DW70.1
Страница 1: ...SERVICE MANUAL DISHWASHERS DW70 1 DW70 3 DW70 4 DW70 5...
Страница 2: ......
Страница 33: ...33 Article no 80 836 38 rev 01...