2 3
FAULT INDICATIONS
INDICATOR LAMPS
I
NDICATION
TYPE OF FAULT
ACTION
DOOR IS OPEN PREVENTING START OF THE SELECTED
CLOSE THE DOOR
PROGRAMME
ELEMENT MALFUNCTION
CONSULT SERVICE
TOO MUCH WATER IN THE MACHINE
SEE SETTING OF WATER /
DRAIN PUMP
A SENSOR ERROR HAS OCCURRED
CONSULT SERVICE
WATERINLET MALFUNCTION
CHECK WATER SUPPLY
(MACHINE WITH LEVELSENSOR)
TROUBLE-SHOOTING PROGRAMME
It will be possible for you to locate the fault if the machine is not working properly. This facilitates the
work of the repair man and reduces repair time. To start the trouble-shooting programme, press the
Temperature selection button five time within 15 seconds. The lamps will flash alternately.
Then press the relevant symbol to see if the appertaining component according to the table below is
working. (Press any programme-button for 3 seconds to exit the test programme).
SYMBOL
TESTS
THE FOLLOWING WILL HAPPEN AFTER CLOSING THE
DOOR IF THERE IS NOTHING WRONG
WATER INLET VALVE
WATER CAN BE HEARD ENTERING
DETERGENT/RINSE-AID DISPENSER
THERE WILL BE A CLICK, AND DETERGENT/RINSE AID WILL BE
INLET VALVE 2
DISPENSED, WATER CAN BE HEARD ENTERING
HEATING ELEMENT
THE ELEMENT HEATS UP. N.B. DO NOT TOUCH THE ELEMENT
CIRCULATION PUMP
THE PUMP STARTS
DRAIN PUMP + FAN MOTOR
THE PUMP STARTS, THE FAN STARTS AND BLOWS OUT AIR
BELOW THE LOWER LEFT CORNER OF THE DOOR