Model D1996FI, SS, and HNDL
(DW 95FI)
Date
2000-06
Page
6
ELECTRICAL FUNCTIONS
ELECTRICAL SUPPLY
The machines are wired for connection to a single-phase, 120V, 15A supply, with a heater power of
1400W, giving a total power requirement of 1600W.
VALUES FOR WIRING DIAGRAMS
Resistance values at 68° F (+/-5°F), 20° C (+/-3°C)
(Values /- 10% is normal.)
AP
Drain pump
120V, 60 Hz, 25.5 ohm
BB
Illumination switch
BE
Internal Illlumination
120V, 51 ohm
CP
Main pump
120 V, 60 Hz, Main = 10.5 ohm, Aux = 14.5 ohm
K D
Combi-dispenser
120 V, 0.31 ohm
EL
Heating element
120 V, 1400 W, 10 ohm
F
Filter
680 K ohm (1-2,3-4)
IV
Inlet valve
120 V, 9.93K ohm
FL
Fan
120 V, 0.25K ohm
LB
Door switch
LU
Door
N
Level switch
P
Control unit
T
Thermostat
19–25 K ohm
TB
Pushbutton switch
TTE
Temp. thermistor
18–25 K ohm
WAX
Wax motor
1.5–3.0 K ohm
VMG
Rinse ag sensor
OB
Overflow switch