SERVICE INFORMATION
Product:
DW95
Date:
98-03-13
TOPIC:
WATER LEVEL
Switch level transferred to measuring points on the coil arm bearing.
Timer-controlled machines
Water flow inlet valve = 3.8 +/- 5% ltr / min
Water flow inlet valve = 3.8 +/- 5% ltr / min
Intake time = 60 seconds
Intake time = 57 seconds
Max. tol. 3.8 +5% = 3.9 ltr
+3 mm
Electronic machines
Point of reference
Point of reference
Max. tol. 3.8 +/- 5% = 3.9 ltr
+2 mm
Max. tol. 3.8 -5% = 3.9 ltr
+1 mm
Max. tol. 3.8 +5% = 3.7 ltr
+1 mm
Max. tol. 3.8 +/- 5% = 3.51 ltr +0 mm
Max. tol. 3.8 -5% = 3.3 ltr
-1 mm
Note:
Start with dry bottom well, which gives a 2mm lower level.