27
FAULT INDICATIONS
INDICATOR LAMPS
IINDICATION DISPLAY
TYPE OF FAULT
ACTION
DOOR IS OPEN PREVENTING START OF
CLOSE THE DOOR
THE SELECTED PROGRAMME
ELEMENT MALFUNCTION
CONSULT SERVICE
TOO MUCH WATER IN THE MACHINE
SEE SETTING OF WATER /
DRAINPUMP
A SENSOR ERROR HAS OCCURRED
CONSULT SERVICE
TROUBLE-SHOOTING PROGRAMME
It will be possible for you to locate the fault if the machine is not working properly. This facilitates the
work of the repair man and reduces repair time. To start the trouble-shooting programme, press the
Rinse button five time within 15 seconds. The lamps will flash alternately.
Then press the relevant symbol to see if the appertaining component according to the table below is
working. (Press Start to exit the test programme).
SYMBOL
TESTS
THE FOLLOWING WILL HAPPEN AFTER CLOSING THE
DOOR IF THERE IS NOTHING WRONG
WATER SOFTENER INLET VALVE
WATER CAN BE HEARD ENTERING (ONLY MACHINES EQUIPPED
WITH WATER SOFTENER)
WATER INLET VALVE
WATER CAN BE HEARD ENTERING
DETERGENT/RINSE-AID DISPENSER
THERE WILL BE A CLICK, AND DETERGENT/RINSE AID WILL BE
DISPENSED
HEATING ELEMENT
THE ELEMENT HEATS UP. N.B. DO NOT TOUCH THE ELEMENT
CIRCULATION PUMP
THE PUMP STARTS
DRAIN PUMP
THE PUMP STARTS
FAN MOTOR
THE FAN STARTS AND BLOWS OUT AIR BELOW THE LOWER
LEFT CORNER OF THE DOOR
Содержание D1976
Страница 19: ...19 ...