Preparation for Work - 1
FRONT PANEL
Input Cable Connection / Controls and Usage Features :
Check the input voltage, phases and frequency before operating the machine. Input voltage
values to be used are specified on the “Specifications” section in the operation manual and
on the plate on the machine. Ensure that grounding of the cables connecting the machine
to the mains is proper and that current required for the normal operation of the machine
can be supplied. Welding machine can be connected to a network protected with a 30 A
delayed fuse only with the cable supplied on the machine.
1-
This machine is designed to operate with a 3-phase supply voltage of 380 V (AC)
at 50 - 60 Hz. It shall only be used with 3-phase grounded systems.
2-
There are no plugs supplied with the machine. Select a plug proper for the
connection point and install the yellow-green cable on the supply cable to the
grounding point of the plug to perform the power connection. Plug and outlet
ratings shall not be lower than the maximum current and voltage.
3-
Never perform the mains connection and operate the machine without a protective
ground connection