52
To replace the lamp, follow the steps below:
1. Power off the projector and unplug the power
cord. Then let the project cool for at least 45
minutes.
2. Loosen the screws on the lamp cover and open
the cover.
3. Make sure the lamp is well protected and
remove two screws. Hold the handle and pull
out the lamp.
4. Install a new lamp with the same model and
tighten the two screws. Make sure the
installation is correct. Put lamp cover in place
and then tighten the screws.
5. Plug the AC power cord and power on the
projector.
Screw
Handle
Lamp
Screw
Screw
Lamp
cover
Note:
When the lamp isn’t illuminated, it may indicate that the lamp has been damaged.
When you replace the lamp in a projector installed on the ceiling, you should stand beside the lamp
cover but not under it; for the broken glass may fall down to hurt you. To do that, remove the lamp
cover gently to avoid being hurt by the dropped glass. If glass drops into your eyes or mouth, you
should see the doctor immediately.
Note:
Note:
As temperature inside the projector is high, you
should cool the projector for at least 45 minutes
before you open the lamp cover.
For the sake of safety, only use the lamp of the
same model. Never drop the lamp onto the ground
nor touch the glass bulb! The glass can shatter and
hurt.
Maintenance
Replacing the lamp
When the service life of the projection lamp is over, the
icon suggests that the lamp needed to be replaced will
appear on the screen, and the indicator for the
replacement will flash yellow. If so, you should
immediately replace it with a new one of the same model.
The flashing time of the replacement indicator is subject
to the lamp mode.