1.5.2
Operating Range
Minimum data rate
300 Baud
Maximum data rate
250 kBaud guaranteed
500 kBaud typically
Input Treshold Low RS232
min. 0.8 V
typ. 1.5 V
Input Treshold High RS232
max. 2.4 V
typ. 1.8 V
Output voltage Swing
1
min. ± 5 V
typ. ± 5.4 V
Short-circuit tolerance
No limit
Short-circuit current
maximum ± 60 mA
Operating system
Windows
2
32/ 64-bit
Linux 1.5.0 32/64-bit
MAC OS 10 32/64-bit
Windows CE
3
RS232
full implementation
RS232 connector
DB9
USB 1.1 a 2.0 compatibility
yes, 12 Mbps (Full Speed)
USB connector
A type
Length of USB cable
1 m
Transmit indicator
red LED
Receive indicator
green LED
1 Outputs Loaded with 3 k
Ω
.
2 Windows XP, Windows Server 2003, Windows Vista, Windows Server 2008, Windows 7,
Windows 8, Windows Server 2008 R2
3 Windows Mobile 2003, Windows Mobile 2003 SE, Windows Mobile 5, Windows Mobile 6,
Windows Mobile 6.1 ,Windows Mobile 6.5
TB. 3: Operating Range
1.5.3
Certificates
CE
EN 55022 ed.3:2011
EN 55024 ed.3:2011
Immunity
EN61000-4-2, class B
EN61000-4-3, class A
10 V/m
EN61000-4-8, class A
EN55024, class A
TB. 4: List of certificates