background image

8

Operating Manual - Powerflex Multi-Channel Power Amplifier

7.2

Input Ground Switch

This switch separates internal circuit ground from

the chassis ground on all inputs.  Ground connections from
an incoming signal are always connected to internal cir-
cuit ground, but float from the chassis ground as long as
the switch is out.  Unless there are special circumstances
which require the circuit ground and chassis ground to be
connected, it is best to leave this switch out.

7.3

Multi-Channel Operation

The Powerflex 6250 is essentially three stereo

amplifiers in one chassis, for a total of up to six separate
channels.  Similarly, the Powerflex 4400 is essentially two
stereo amplifiers in one chassis, for a total of up to four
separate channels.  Thus, the following references to Ste-
reo, Mono, or Bridged operation is with regard to each
pair
 of channels in the amplifier.  For example, Channel 1
and Channel 2 together can provide stereo, mono, or
bridged operation, completely independent of Channels 3-
4 or Channels 5-6 settings (6250 only).

7.4

50Hz Low Cut Switch

Each pair of channels has a 50Hz second order

(12 dB per octave) low-cut filter option which is applied
to both channels within the pair.  When the switch is
pressed, the audio signal is -3dB at 50Hz, -15dB at 25 Hz,
-27dB at 12.5Hz, etc.

7.5

Input Level Controls

Input Level Controls attenuate input signal from

0dB down to -

.  For best performance, Ashly recommends

that the level controls be operated at full level (0 dB at-
tenuation).

In STEREO mode, each level control corresponds

directly to the input signal on its respective channel.

In MONO Mode, the input signal connected to

channels 1, 3, or 5 are used to drive channels 2, 4, or 6
respectively, and the level controls for channels 1, 3, and
5 likewise control channels 2, 4, and 6.  When switched to
Mono mode, channels 2, 4, or 6 level controls become in-
active.

In BRIDGED mode, the level controls function

the same as in mono mode.

7.6

Stereo/Mono Switch

Powerflex amplifiers are comprised of two (4400)

or three (6250) stereo amplifiers, each operating indepen-
dently of the others, with Stereo/Mono switching avail-
able for each channel pair.  If this switch is set to Stereo
mode, the channel pair operates as two discrete amplifi-
ers, each with its own input connection and level control.

Switching to Mono mode allows one input (chan-

nel 1, 3, or 5) to drive both channels of a stereo channel
pair.  Pressing the Mono switch disables the channel pair's
other input connection, as well as its level control.  The
first channel's input and level control now determines the
signal to both channels.

7.7

Dual Channel/Bridge Mode Switch

Bridging a power amplifier is the process whereby

two channels are supplied the same signal, with the sec-
ond channel's phase inverted 180°.  The speaker is then
connected across the (+) output connections of each chan-
nel, resulting in twice the power to the speaker that either
channel could deliver by itself.  Since in Bridge Mode both
connections have voltage present, never connect or touch
either speaker wire to ground. 
 In the Powerflex 6250, use
Bridge mode for 70V applications as well.

115V

115V or 230V

50-60Hz

1400W

AC

Replace Only With 

Same Type Fuse.

Refer To Owner's Manual

For Proper Fuse Rating.

Ch 1 In

(Mono)

Ch 2 In

Ch 3 In

(Mono)

Ch 4 In

Ch 5 In

(Mono)

Ch 6 In

Ch2

Ch1

Ch4

Ch6

Input

1

2

3

5 6

7

8

9

0

4

10

1

2

3

6

7

8

9

0

10

Mono

Stereo

Bridge

Dual

LoCut

Norm

Ch.

1-2

(1-2 Mono)

Ch1

50Hz

1

2

3

6

7

8

9

0

4

10

1

2

3

6

7

8

9

0

10

Bridge

Dual

LoCut

Norm

50Hz

1

2

3

7

8

9

0

4

10

1

2

3

6

7

8

9

0

10

Bridge

Dual

LoCut

Norm

50Hz

Ch2

(3-4 Mono)

Ch3

Ch4

(5-6 Mono)

Ch5

Ch6

Chassis

Float

Ground

Ch.

3-4

Ch.

5-6

(-)

(+)

2

3

1

5

5

5

6

5

5

Mono

Stereo

Mono

Stereo

- +

Ground

+ -

- +

Ground

+ -

- +

Ground

+ -

(Mono)

Ch3

(Mono)

Ch5

(Mono)

PUSH

PU SH

PU SH

PU SH

PU SH

PU SH

*
P o w e r f l e x
6250 shown -
P o w e r f l e x
4400 only has
inputs 1-4.

Содержание Powerflex 4400

Страница 1: ...bster NY 14580 9103 Phone 716 872 0010 Toll Free 800 828 6308 Fax 716 872 0739 www ashly com Channel 1 Channel 2 Channel 3 Channel 4 Protect Thermal Clip Signal Power Powerflex 4400 Channel 1 Channel...

Страница 2: ...nput Connectors 7 7 2 Input Ground Switch 8 7 3 Multi Channel Operation 8 7 4 Input Level Controls 8 7 5 Stereo Mono Switches 8 7 6 Dual Channel Mode Bridge Mode Switches 8 7 7 50Hz Low Cut Switches 8...

Страница 3: ...NO USER SER VICEABLE PARTS INSIDE REFER SERVICING TO QUALIFIED SERVICE PERSONNEL TO REDUCE THE RISK OF FIRE OR ELECTRICAL SHOCK DO NOT EXPOSE THIS APPLIANCE TO RAIN OR MOISTURE TO REDUCE THE RISK OF...

Страница 4: ...l as preserving its own 2 UNPACKING As a part of our system of quality control every Ashly product is carefully inspected before leaving the factory to ensure flawless appearance After unpacking pleas...

Страница 5: ...ft run of different gauges of 2 conduc tor copper speaker wire Wire Gauge 100ft 8 load 4 load 8 0605 0 8 1 5 10 1018 1 3 2 5 12 1619 2 0 4 0 14 2575 3 2 6 4 16 4094 5 1 10 2 18 6510 8 1 16 3 Table 4...

Страница 6: ...sink extrusions reaches 85 to 90 C Both channels of the affected amplifier module will shut off until the measured temperature drops below about 70 C The amplifier should be able to maintain proper o...

Страница 7: ...er sists try connecting a balanced signal to the Euroblock input with the input cable s shield lifted at the amplifier end of the cable ie no ground connection but connected to ground at the signal so...

Страница 8: ...de channels 2 4 or 6 level controls become in active In BRIDGED mode the level controls function the same as in mono mode 7 6 Stereo Mono Switch Powerflex amplifiers are comprised of two 4400 or three...

Страница 9: ...er 115VAC or 230VAC mains Switching from one to the other simply requires the fol lowing steps 1 Unplug the amplifier from the wall and re move the power cord from the rear of the amplifier 2 Using a...

Страница 10: ...stated requirements or im proper AC inlet mains voltage setting make sure nominal AC mains voltage matches the number in the viewing win dow on the AC inlet 8 3 Output overcurrent more than 15 to 20 a...

Страница 11: ...al Bridge Switches Out Levels Controls Used Per Input Channel Speaker Outputs Up To Six Different Outputs Minimum Speaker Load Per Channel 4 Up To Six Different Amplifier Inputs Six Channel Setup dual...

Страница 12: ...up Possible Applications 70 Volt Constant Voltage Systems 6250 Only Subwoofers High Powered Monitors High Powered Full Range PA Speakers Bridged Channels 1 2 From Channel 1 Input Bridged Channels 3 4...

Страница 13: ...mplifier module Specification Notes Due to its spread spectrum out put switching pattern the output signal of a Powerflex ampli fier contains significant dynamic frequency content far outside the audi...

Страница 14: ...r damaged speaker drivers that could cause distorted sound 12 POWERFLEX DIMENSIONS Channel 1 Channel 2 Channel 3 Channel 4 Channel 5 Channel 6 Pr ot ect Thermal Cli p Signal Po wer Powerflex 6250 16 9...

Страница 15: ...____________________ Dealer ______________________________________ Date of Purchase _______________________________ Dealer s Address _______________________________ ___________________________________...

Страница 16: ...nnel Power Amplifier Printed in USA 10 01 6250 3 ASHLY AUDIO INC 847 Holt Road Webster NY 14580 9103 Phone 716 872 0010 Fax 716 872 0739 Toll Free 800 828 6308 www ashly com 2001 by Ashly Audio Corpor...

Отзывы: