background image

11

Operating Manual - Powerflex Multi-Channel Power Amplifier

9.

TYPICAL APPLICATIONS

The Powerflex 6250 is essentially three stereo amplifiers in one chassis, each with dual stereo, dual mono, and

bridged mono capabilities, while the Powerflex 4400 is two stereo amplifiers (four channels), but with more power per
channel than the 6250.  The ability to easily mix and match various configurations is what puts the "flexibility" in
Powerflex.  Input connections can be 1/4" phone plug, XLR, or hard-wired with two-piece Euroblock connectors, while
speaker outputs can be either "banana" type plugs or wire crimped spade terminals.  Note:  The Powerflex 6250 is used
for the following application details, but the 4400 is used in a similar fashion, to a maximum of four channels.

9.1  Individual Channel Setup

+

-

Bridge/70V

Ch1

(+)

(-)

Ch2

(+)

(-)

+

-

Bridge/70V

Ch3

(+)

(-)

Ch4

(+)

(-)

+

-

Bridge/70V

Ch5

(+)

(-)

Ch6

(+)

(-)

OUTPUTS

Ashly Audio Inc.

Made In USA

Powerflex 6250

- +

Ground

+ -

Ch 1 In

Ch 2 In

- +

Ground

+ -

Ch 3 In

Ch 4 In

- +

Ground

+ -

Ch 5 In

Ch 6 In

Ch2

Ch1

Ch3

Ch4

Ch5

Ch6

Input

1

2

3

5 6

7

8

9

0

4

10

1

2

3

6

7

8

9

0

10

Mono

Stereo

Bridge

Dual

LoCut

Norm

Ch.

1-2

(1-2 Mono)

Ch1

50Hz

1

2

3

6

7

8

9

0

4

10

1

2

3

6

7

8

9

0

10

Mono

Stereo

Bridge

Dual

LoCut

Norm

50Hz

1

2

3

6

7

8

9

0

4

10

1

2

3

6

7

8

9

0

10

Mono

Stereo

Bridge

Dual

LoCut

Norm

50Hz

Ch2

(3-4 Mono)

Ch3

Ch4

(5-6 Mono)

Ch5

Ch6

Chassis

Float

Ground

Ch.

3-4

Ch.

5-6

5

5

5

5

5

 

"

$

Input Section:
Up to Six Different Inputs
Stereo/Mono Switches - Out
Dual Bridge Switches - Out
Levels Controls - Used Per Input Channel

Speaker Outputs - Up To Six Different Outputs

Minimum Speaker Load Per Channel = 4

 

 

!

"

#

$

Up To Six Different Amplifier Inputs

Six Channel Setup 

(dual stereo)

Multi-Media Systems
Surround Sound
Three Way Biamplification
Stereo Triamplification

Possible Applications:
Multiple Zone Systems
Three Pairs Of Studio Monitors
Multiple Stage Monitors
25V Distributed Systems (6250 Only)

(Mono)

(Mono)

(Mono)

(Mono)

(Mono)

(Mono)

!

#

9.2  Dual Mono Setup

+

-

Bridge/70V

Ch1

(+)

(-)

Ch2

(+)

(-)

+

-

Bridge/70V

Ch3

(+)

(-)

Ch4

(+)

(-)

+

-

Bridge/70V

Ch5

(+)

(-)

Ch6

(+)

(-)

OUTPUTS

Ashly Audio Inc.

Made In USA

Powerflex 6250

- +

Ground

+ -

Ch 1 In

Ch 2 In

- +

Ground

+ -

Ch 3 In

Ch 4 In

- +

Ground

+ -

Ch 5 In

Ch 6 In

Ch2

Ch1

Ch3

Ch4

Ch5

Ch6

Input

1

2

3

5 6

7

8

9

0

4

10

1

2

3

6

7

8

9

0

10

Mono

Stereo

Bridge

Dual

LoCut

Norm

Ch.

1-2

(1-2 Mono)

Ch1

50Hz

1

2

3

6

7

8

9

0

4

10

1

2

3

6

7

8

9

0

10

Mono

Stereo

Bridge

Dual

LoCut

Norm

50Hz

1

2

3

6

7

8

9

0

4

10

1

2

3

6

7

8

9

0

10

Mono

Stereo

Bridge

Dual

LoCut

Norm

50Hz

Ch2

(3-4 Mono)

Ch3

Ch4

(5-6 Mono)

Ch5

Ch6

Chassis

Float

Ground

Ch.

3-4

Ch.

5-6

5

5

5

5

5

!

#

Input Section:
Up to Three Different Inputs
Stereo/Mono Switches - In
Dual Bridge Switches - Out
Levels Controls - Only Channels 1, 3, or 5 Used

Minimum Speaker Load Per Channel = 4

 

!

"

#

$

Amplifier Inputs

(An Input Can Be Parallel Connected
To Other "Non-Partner" Channels by 

Hard-Wire Jumping the Euroblock Connectors) 

Dual Mono Setup

Possible Applications:
Multiple Zone Systems
Three Different Stage Monitor Mixes
Dual-Mono FOH Tri-Amplification

Channels 1 & 2 

From Channel 1 Input

Channels 3

 & 

From Channel 3 Input

Channels 5

 & 

From Channel 5 Input

(Mono)

(Mono)

(Mono)

(Mono)

(Mono)

(Mono)

Содержание Powerflex 4400

Страница 1: ...bster NY 14580 9103 Phone 716 872 0010 Toll Free 800 828 6308 Fax 716 872 0739 www ashly com Channel 1 Channel 2 Channel 3 Channel 4 Protect Thermal Clip Signal Power Powerflex 4400 Channel 1 Channel...

Страница 2: ...nput Connectors 7 7 2 Input Ground Switch 8 7 3 Multi Channel Operation 8 7 4 Input Level Controls 8 7 5 Stereo Mono Switches 8 7 6 Dual Channel Mode Bridge Mode Switches 8 7 7 50Hz Low Cut Switches 8...

Страница 3: ...NO USER SER VICEABLE PARTS INSIDE REFER SERVICING TO QUALIFIED SERVICE PERSONNEL TO REDUCE THE RISK OF FIRE OR ELECTRICAL SHOCK DO NOT EXPOSE THIS APPLIANCE TO RAIN OR MOISTURE TO REDUCE THE RISK OF...

Страница 4: ...l as preserving its own 2 UNPACKING As a part of our system of quality control every Ashly product is carefully inspected before leaving the factory to ensure flawless appearance After unpacking pleas...

Страница 5: ...ft run of different gauges of 2 conduc tor copper speaker wire Wire Gauge 100ft 8 load 4 load 8 0605 0 8 1 5 10 1018 1 3 2 5 12 1619 2 0 4 0 14 2575 3 2 6 4 16 4094 5 1 10 2 18 6510 8 1 16 3 Table 4...

Страница 6: ...sink extrusions reaches 85 to 90 C Both channels of the affected amplifier module will shut off until the measured temperature drops below about 70 C The amplifier should be able to maintain proper o...

Страница 7: ...er sists try connecting a balanced signal to the Euroblock input with the input cable s shield lifted at the amplifier end of the cable ie no ground connection but connected to ground at the signal so...

Страница 8: ...de channels 2 4 or 6 level controls become in active In BRIDGED mode the level controls function the same as in mono mode 7 6 Stereo Mono Switch Powerflex amplifiers are comprised of two 4400 or three...

Страница 9: ...er 115VAC or 230VAC mains Switching from one to the other simply requires the fol lowing steps 1 Unplug the amplifier from the wall and re move the power cord from the rear of the amplifier 2 Using a...

Страница 10: ...stated requirements or im proper AC inlet mains voltage setting make sure nominal AC mains voltage matches the number in the viewing win dow on the AC inlet 8 3 Output overcurrent more than 15 to 20 a...

Страница 11: ...al Bridge Switches Out Levels Controls Used Per Input Channel Speaker Outputs Up To Six Different Outputs Minimum Speaker Load Per Channel 4 Up To Six Different Amplifier Inputs Six Channel Setup dual...

Страница 12: ...up Possible Applications 70 Volt Constant Voltage Systems 6250 Only Subwoofers High Powered Monitors High Powered Full Range PA Speakers Bridged Channels 1 2 From Channel 1 Input Bridged Channels 3 4...

Страница 13: ...mplifier module Specification Notes Due to its spread spectrum out put switching pattern the output signal of a Powerflex ampli fier contains significant dynamic frequency content far outside the audi...

Страница 14: ...r damaged speaker drivers that could cause distorted sound 12 POWERFLEX DIMENSIONS Channel 1 Channel 2 Channel 3 Channel 4 Channel 5 Channel 6 Pr ot ect Thermal Cli p Signal Po wer Powerflex 6250 16 9...

Страница 15: ...____________________ Dealer ______________________________________ Date of Purchase _______________________________ Dealer s Address _______________________________ ___________________________________...

Страница 16: ...nnel Power Amplifier Printed in USA 10 01 6250 3 ASHLY AUDIO INC 847 Holt Road Webster NY 14580 9103 Phone 716 872 0010 Fax 716 872 0739 Toll Free 800 828 6308 www ashly com 2001 by Ashly Audio Corpor...

Отзывы: