7
Installation
Back wall / Arrière Mur
Side w
all / P
ar
oi La
tér
ale
Side w
all / P
ar
oi La
tér
ale
Back wall / Arrière Mur
Side w
all / P
ar
oi La
tér
ale
Side w
all / P
ar
oi La
tér
ale
Back w
all / A
rr
ièr
e M
ur
Ceiling / Plafond
Floor Protector / Protection de Plancher
C
B
A
E
E
D
D
F
G
K
H
L
J
M
M
FLOOR PROTECTOR
The stove must be placed on solid concrete, solid masonry, or when installed on a combustible floor, on a
Type 2 floor protector listed to standard UL 1618 with a minimum R value of 1.03 and a minimum thickness of
1/2” or equivalent. The floor protector is required to provide heat, live ember, and ash protection and must
be of a non-combustible, continuous solid surface to protect against infiltration of live embers and ash. For
UL Listed floor protectors, refer to manufacturers instructions for installation directions. Manufacturers of listed
floor protectors include Imperial Metal Products and Hy-C among others. To calculate R-Values for alternative
methods, see Alternate Floor Protector Calculation Methods in the back of this manual.
Dimension
Inch mm
H*
Front
9
229
J
Flue rear
2
51
K**
Left
8
203
L**
Right
8
203
M
Flue Side
2
51
•
Canadian installations require 18” (457mm)
•
Canadian installations require 8” (203mm)
INSERT STOVE INSTALLATION
The installer must attach a metal tag as required by UL1482 Clause 5.1.11 using screws or nails to the fireplace, in a location
readily visible should the fireplace insert be removed, if the fireplace has been modified to accommodate the fireplace insert.
H
B
H
A
E
F G
D
A
I
C
Thermal Protection Requirements
A
B
C
D
E
F
G
H
I
9
48
32
1/2
9
16
21
8
12