Operation
by turning the dampener to the left a little bit.
As a general rule, on lower feed rate settings, the damper
should be farther to the left closing it off. On higher feed
rates, the damper should be open more by having it set more
towards the right. Through trial and error, you will
fi
nd the best
setting. Consult your dealer if you need help.
NOTE: On heat range “1”, damper should be either completely
closed or open no more than a ¼ of the way. If damper is
open to far, it can cause the
fi
re to go out.
OPENING DOOR
If the door is opened while the stove is in operation it must
be closed within 30 seconds or the stove will shut down. If
the stove shuts down push the “On/Off” button to re-start
your stove. The stove will have to fully shut down and turn
off before you will be able to restart the stove.
ROOM AIR FAN
When starting your stove the Room Air Fan will not come on
until the stove’s heat exchanger warms up. This usually takes
about 10 minutes from start-up.
IF STOVE RUNS OUT OF PELLETS
The
fi
re goes out and the auger motor and blowers will run until
the stove cools. This will take 30 minutes or longer depend-
ing on the heat remaining in the appliance. After the stove
components stop running all lights on the display will go out
and the two digit display will begin
fl
ashing “E3”
REFUELING
The hopper and stove top will be hot during operation; there-
fore, you should always use some type of hand protection
when refueling your stove.
Never place your hand near the auger while the stove is in
operation.
We recommend that you not let the hopper drop below ¼
full.Attempts to achieve heat output rates that exceed heater
design speci
fi
cations can result in permanent damage to the
heater.
KEEP HOPPER LID CLOSED AT ALL TIMES EXCEPT
WHEN REFILLING. DO NOT OVERFILL HOPPER.
SHUTDOWN PROCEDURE
Turning your stove off is a matter of pressing the “POWER”
button on the display board. The green light will turn back to
red when the “POWER” button is pushed. The auger motor
will stop, and the blowers will continue to operate until the
internal
fi
rebox temperatures have fallen to a preset level.
Your stove is equipped with a high temperature thermodisc.
This unit has a manual reset thermodisc. This safety switch
has two functions.
A. To recognize an overheat situation in the stove and shut
down the fuel feed or auger system.
B. In case of a malfunctioning convection blower, the high-
temperature thermodisc will automatically shut down the au-
ger, preventing the stove from overheating.NOTE: On some
units, once tripped, like a circuit breaker, the reset button will
have to be pushed before restarting your stove. On other
units the thermodisc has no reset button and will reset itself
once the stove has cooled. The manufacturer recommends
that you call your dealer if this occurs as this may indicate a
more serious problem. A service call may be required.
If the combustion blower fails, an air pressure switch will
automatically shut down the auger.NOTE: Opening the stove
door for more than 30 seconds during operation will cause
enough pressure change to activate the air switch, shutting
the fuel feed off. The stove will shut down and show “E2” on
the two digit display. The stove has to fully shut down before
restarting.
TAMPER WARNING
This wood heater has a manufacturer-set minimum low burn
rate that must not be altered. It is against federal regulations
to alter this setting or otherwise operate this wood heater in a
manner inconsistent with operating instructions in this manual.
WARNING: Never shut down this unit by un-
plugging it from the power source.