5
INSTALLATION
INSTALLATION OPTIONS
Freestanding Unit -
Supported by pedestal/legs
and placed on a non-combustible floor surface
in compliance with clearance requirements for a
freestanding stove installation.
Alcove Unit -
Supported by pedestal/legs and
placed on a non-combustible floor surface in
compliance with clearance requirements for an
alcove installation.
IMPROPER INSTALLATION
The use of other components other than stated
herein could cause bodily harm, heater damage,
and void your warranty. The manufacturer will not
be held responsible for damage caused by the
malfunction of a stove due to improper venting or
installation.
FLOOR PROTECTION
This unit must be installed on a non-combustible
floor surface. If a floor pad is used, it should be
certified or equal. The floor pad or non-combustible
surface should be large enough to extend a
minimum of 6” (153 mm) in front, 6” (153 mm) on
each side, and 1” (26 mm) behind the stove. Floor
protection must extend under and 2” (51 mm) to
each side of the chimney tee for an interior vertical
installation. A Floor Protector of 1” (26 mm) thick
is recommended for this installation. Canadian
installations require 18” (450 mm) in front of the
unit.
B
B
D
C
A
B
B
C
Dimensions
in
mm
A Rear (through wall)
1
25
B Side
6
152
C Front
*6 *152
D
Rear (interior vertical)
2
50
* Canada installation requires 18”
(450 mm) in front of the unit.
CLEARANCES
Your pellet stove has been tested and listed for
installation in residential, mobile home, and alcove
applications in accordance with the clearances
given in this manual. NOTE: Distance “B” on the side
of your pellet stove may need to be greater than the
minimum required clearance for suitable access to
the control panel.
E
BACK WALL
BACK WALL
SIDEWALL
SIDEWALL
F
F
G
G
E
ADJACENT
WALL
ADJACENT
WALL
H
ADJACENT WALL
H
H
ADJACENT WALL
H
J
in
mm
Parallel
E Backwall to unit
2
50
F
Sidewall to flue
13
330
G
Sidewall to top edge
8
203
Corner
H
Adjacent wall to unit
8
203
Alcove
J
Alcove depth
36
914
OUTSIDE AIR SUPPLY
(OPTIONAL, UNLESS
INSTALLING IN A MOBILE HOME)
Depending on your location and home
construction, outside air may be necessary for
optimal performance. Your stove is approved to be
installed with an outside air intake (69FAK) which
is necessary for a mobile home. You can purchase
the 69FAK through your heater dealer. Installation
instructions are supplied with the air intake kit.