TROUBLESHOOTING

WARNING

Turn off heater and let cool before servicing. Only a qualified service person should service and 
repair heater.

16

OBSERVED PROBLEM

 

When ignitor button is 
pressed, there is no spark at 
pilot. 
 

 

When ignitor button is 
pressed, there is spark at 
pilot but no ignition.

Pilot lights but flame goes 
out when control knob is 
released. 

POSSIBLE CAUSE
 

1) Ignitor electrode broken.
 
2) Ignitor electrode not connected to 
ignitor cable
.
3) Ignitor cable pinched or wet.

4) Broken ignitor cable.

5) Bad piezo ignitor.

1) Gas supply is turned off or manual 
shutoff valve closed.

2) Control knob not in PILOT 
position.

3) Control knob not pressed in while 
in pilot position.

4) Air in gas lines when installed.

5) Pilot is clogged.

6) Gas regulator setting not correct.

1) Control knob not fully pressed in.

2) Control knob not depressed long 
enough.

3) Manual shutoff valve not fully 
open.

4) Thermocouple connection looses 
at control valve.

5) Pilot flame not touching 
thermocouple, which allows couple 
to cool, causing pilot flame to go out. 
This problem could be caused by 
one or both of the following:

·

Low gas pressure.

·

Dirty or partially clogged pilot. 

6) Thermocouple damaged.

7) Control valve damaged.

REMEDY
 

1) Replace ignitor electrode.
 
2) Reconnect ignitor cable.
 

3) Free ignitor cable if pinched by any
 metal or tubing. Keep ignitor cable dry. 

4) Replace ignitor cable.
 
5) Replace piezo ignitor.
 
1) Turn on gas supply or open manual 
shutoff valve. 

2) Turn control knob to PILOT position. 

3) Press in control knob while in PILOT 
position. 

4) Continue holding down control knob. 
Repeat igniting operation until air is 
removed. 
5) Clean pilot orifice or replace pilot 
assembly. 
6) Replace gas regulator. 

1) Press in control knob fully. 

2) After pilot lights, keep control knob 
pressed in 30 seconds. 

3) Fully open manual shutoff valve. 

4) Hand tighten until snug, then tighten ¼ 
turn more. 

5) a) Contact local gas company. 
    b) Clean pilot or replace pilot     
        assembly.

6) Replace thermocouple.
 
7) Replace control valve.
 

Содержание AGDV12

Страница 1: ...SI VOUS SENTEZ UNE ODEUR DE GAZ Ne pas tenter d allumer d appareils Ne touchez aucun interrupteur Ne pas vous servir des t l phones dans le b timent o vous vous trouvez Appelez imm diatement votre fo...

Страница 2: ...personal injury or loss of life Refer to this manual Installation and service must be performed by a qualified installer service agency or the gas supplier Do not use this appliance if any part has be...

Страница 3: ...Gas Inlet Pressure for purpose of input adjustment The efficiency rating of the appliance is a product thermal efficiency rating determined under continuous operating conditions and was determined ind...

Страница 4: ...ng check local codes Sealant resistant to propane gas Manual shutoff valve Ground joint union Test gauge connection Sediment trap Tee joint Pipe wrench The installation location shall provide the foll...

Страница 5: ...ted above the terminal within a horizontal distance of 2 feet 61 cm from the center line of the terminal D 12 inches 30 cm 1 2 M Clearance to unventilated soffit E Clearance to outside corner F Cleara...

Страница 6: ...Clothing or other flammable material should not be placed on or near the appliance Any safety screen or guard removed for servicing an appliance must be replaced prior to operating the appliance Inst...

Страница 7: ...HE HANGING BRACKET ON A WOODEN WALL 1 Taking into account the minimum clearances mentioned in figure 4 locate the closest wall stud which will serve to hold the appliance and mark the hole center at a...

Страница 8: ...ging bracket and drill the four holes 6 Insert in each hole the anchors provided 7 Place back the hanging bracket and fix it with four screws MOUNTING THE HEATER ON HANGING BRACKET Place the heater on...

Страница 9: ...ppareil sont utilis es CAUTION ALL JOINTS MUST BE AIR TIGHT The venting system consists of one injected aluminum cap A one vent pipe B one vent air intake pipe C one rod D one nut E one outdoor mounti...

Страница 10: ...nsor from any damage during shipping or while handling it before it is definitely installed the thermostat sensor has not been attached to its final location in the appliance So once the heater is ins...

Страница 11: ...auge connections upstream of the gas supply connection to the heater Figure 21 WARNING For L P Gas use PRESSURE REGULATED gas supply Do not directly connect LP supply tank to the pressure regulator on...

Страница 12: ...excess of psi 3 5 kPa The appliance must be isolated from the gas supply piping system by closing equipment shutoff valve during any pressure testing of the gas supply piping system at test pressures...

Страница 13: ...R gler le thermostat la temp rature la plus basse 4 Appuyez doucement sur le bouton et tournez le en direction des aig illes d une montre jusqu la position OFF Ferm e Ne la forcez pas NB On ne peut to...

Страница 14: ...m the manufacturing process It is recommended to burn a new wall furnace for at least two 2 hours the first time that it is used CLEANING AND MAINTENANCE WARNING Turn off heater and let cool before cl...

Страница 15: ...OUPLE PRIMARY FLAME SECONDARY FLAME SECONDARY FLAME PRIMARY FLAME THERMOCOUPLE PILOT FLAME Fig 26 Correct main burner flame pattern top view Model AGDV20 Cleaning the Main Burner Orifice and Main Burn...

Страница 16: ...rmocouple connection looses at control valve 5 Pilot flame not touching thermocouple which allows couple to cool causing pilot flame to go out This problem could be caused by one or both of the follow...

Страница 17: ...clogged burner orifice 1 Metal expanding while heating or contracting while cooling 1 Gas leak see WARNING statement below 1 Low line pressure 2 Pilot is partially clogged 1 Gas leak See WARNING state...

Страница 18: ...authorized distributor A UNDER WARRANTY Contact authorized dealers of this product If they are unable to supply original replacement part s call the authorized distributor Be prepared to indicate name...

Страница 19: ...30 00 hour Speci cally not covered under the terms of this limited warranty or any other warranty are problems relating to smoking or sooting which is entirely related to the installation of the heat...

Страница 20: ...Model AGDV8 20...

Страница 21: ...Model AGDV12 21...

Страница 22: ...Model AGDV20 22...

Страница 23: ...232 01001901 Thermostat Sensor bracket 18 05078 Knob support 21 05083 05228 05334 Bracket 22 01082001 01081403 02230113 01082102 01082002 01081403 Burner orifice Natural Gas Burner orifice L P G 23 01...

Страница 24: ...0 Burner tubing 48 02830109 02830137 02830141 Pilot tubing 49 011935 Nut 50 01024001 02810150 Gas main inlet tubing 51 05087 05240 Radiation shield 52 01052001 01052002 Pressure Regulator Natural Gas...

Отзывы: