Features and Benefits

•  Features an 18 in. x 30 in., 30 Gal.; or 24 in. x 24 in., 45 Gal., heavy duty sewage basin with a water-tight snap-in    

  molded inlet hub

•  Ultra strong cover comes with 2 in. threaded discharge and vent flanges, a molded cord grommet, a molded 

  reusable cover seal and eight stainless screws and washers to secure the cover to the basin

•  Automatic, all cast-iron sewage pump passes 2 in. solids and features 20 ft. power and piggyback float 

  switch cords

•  System pumps up to 125 GPM

•  Ultra quiet, heavy duty ABS slip fit, flexible union check valve passes a full 2in. solid

Performance (Gallon Per Minute)  

 

 

 

  Float Switch

Model  

 

 

 0’ 

  5’    10’    15’    20’    On      Off 

Solids 

Handling

SW40WB1830 

          110      105    85    61    20   15.5”     7.5”  

 2”

SW50WB1830 

          125      116    98    75    48   15.5”     7.5”  

 2” 

 

Features

Please contact 1-855-281-6830 for further assistance    ashlandpump.com

2

Содержание SW40WB2424

Страница 1: ...g this pump system Take the time to read the instructions carefully before using this product We strongly recommend that you keep this instruction manual in a safe place for future reference SW40WB183...

Страница 2: ...rs to secure the cover to the basin Automatic all cast iron sewage pump passes 2 in solids and features 20 ft power and piggyback float switch cords System pumps up to 125 GPM Ultra quiet heavy duty A...

Страница 3: ...with automatic reset thermal overload protection Ball bearings for quiet operation Handles 2 solids Easily replaceable 20 foot power cord Mechanical shaft seal for long life Support 400 lbs Sewage Pu...

Страница 4: ...ith a float cord and a 1 hole grommet for 1 cord systems Press the grommet B into the grommet hole 4 to provide a tight seal Secure the basin cover onto the basin with the basin cover fasteners remove...

Страница 5: ...lve C and connect this pipe to the appropriate sewer main pipe for discharge Hand tighten the fittings to ensure a watertight seal 5 Attaching the vent connection Install a 2 in PVC Schedule 40 thread...

Страница 6: ...to shut off service to the house or call your local fire department for instructions Remove pump and repair or replace Failure to follow this warning can result in fatal electrical shock WARNING Exte...

Страница 7: ...to be submerged WARNING Do not use extension cords They are a fire hazard and can reduce voltage sufficiently to prevent pumping and or damage the motor WARNING Do not handle or service the pump while...

Страница 8: ...ng your Ashland Pump product Without limiting the foregoing Ashland Pump specifically disclaims the implied warranties of merchantability and fitness for a particular purpose No warranties or represen...