IM-T5500E-E-Rev 0   08/2014                                                                                                         Page 1 of 11 

P/N 095I105-01EN 

 

 

Installation and Maintenance  

Instruction Manual 

 

Bourdon tube pressure gauge with integrated transmitter, model T5500E 

for industrial application 

In the following configuration: 

  100=T5500E### bourdon tube pressure gauge with integrated transmitter 

 

Содержание t5500e

Страница 1: ...5 01EN Installation and Maintenance Instruction Manual Bourdon tube pressure gauge with integrated transmitter model T5500E for industrial application In the following configuration 100 T5500E bourdon...

Страница 2: ...g on the device 5 5 Construction and function 6 5 1 Overview 6 5 2 Description of function 6 5 3 Description of components 6 5 4 Accessories 6 6 Transport 7 6 1 Safety 7 6 2 Transport inspection 7 6 3...

Страница 3: ...ing This indicates a possibly hazardous situation where failing to follow advice may result in risks to people animals the environment and buildings Information This emphasizes key information for eff...

Страница 4: ...e will be no output 2 1 2 Freezing Prohibit freezing of media in pressure port Unit should be drained mount in vertical position to prevent possible overpressure damage from frozen media 2 1 3 Static...

Страница 5: ...t The device may only be installed and started up by specialist staff familiar with installation start up and operation of the product Specialist staff are defined as those individuals capable of asse...

Страница 6: ...ce and pointer pursuant to EN 837 1 nominal size 100 mm Erl uter ung zus tzlich ei n Hi nweis 5 3 2 Instrument connection The instrument connection is located on the bottom side of the pressure gauge...

Страница 7: ...sured the scope of the measurement range and of the protection against special conditions such as vibrations pulsations and pressure spikes A bracket must be installed to support the pressure gauge if...

Страница 8: ...nduit that contains high current AC power cables Where possible avoid running the cable near inductive equipment Units with shielded cable electrical termination connect the drain wire to the guard te...

Страница 9: ...secured against being switched on again 8 2 Check on function and recalibration Inspection of function and recalibration should be at regular intervals The precise testing cycles should be adjusted i...

Страница 10: ...acement of the pressure gauge is required in the event any of the above exist 9 4 Conduct following fault rectification See Chapter 7 3 Mounting Installation 10 Removal disposal 10 1 Safety Residue fr...

Страница 11: ...Page 11 of 11 11 2 CE Declaration of conformity...