background image

ASG, Division of Jergens, Inc.  

15700

 S. Waterloo Road | Cleveland, OH 44110-3898 | Phone: (888) 486-6163 | Fax: (216) 481-4519 | Email: [email protected] | www.asg-jergens.com

Page 11 of 15

The Auto-Reset feature is used to automatically reset the reading value in peak mode.  
This mode works when the reading value is higher than the setting value, causing the 
peak value to change to a new held value.  The user does not need to press the 

RESET

 

key, since the peak value will automatically reset.  This feature works in peak mode 
only.  If this feature is activated, the icon “AR” will display on main display. 
•  To set Auto-Reset, press the 

MENU/ESC

 key, the display will show the main 

menu page.  Use the 

UP

 and 

DOWN ARROW

 keys to move the cursor point to 

SETTING

.  Press the 

ENTER

 key and use the 

UP

 and 

DOWN

 

ARROW

 keys to 

move the cursor point to A

UTO-RESET

.  Press the 

ENTER

 key.  The display will 

show the Auto-Reset menu page.

•  Press the 

ESC

 key to return the main menu page

•  Use the 

UP

 and 

DOWN ARROW 

keys to change the value. Use the 

RIGHT ARROW

 

key to change the unit.  Press 

ZERO

 key to reset value to zero.  Press 

ENTER 

key to 

set new value and return to setting menu.  Press 

ESC

 to return to setting menu.

•  Auto-Reset feature will automatically be disabled if you set 

AUTO-RESET

 = 0

•  To set Auto-Shutdown, press the 

MENU/ESC

 key, the display will show the main 

menu page. Use the 

UP

 and 

DOWN ARROW

 keys to move the cursor point to 

SETTING

.  Press the 

ENTER

 key and use the 

UP

 and 

DOWN

 

ARROW 

keys to 

move the cursor point to 

AUTO-SHUTDOWN

.  Press the 

ENTER 

key.  The display 

will show the Auto-Shutdown menu page.

•  The Auto-Shutdown feature can be enabled to conserve battery power where the 

meter powers down after 5, 10, and 15 minutes (depending on auto-shutdown 
time) since the last key press.  Use the 

UP

 and 

DOWN ARROW

 keys to move the 

cursor to the auto-shutdown time preferred and press 

ENTER.

•  Press 

ESC

 key to return to the main menu page.  If you activate this feature, 

the 

OFF

 symbol will be displayed on the main display.

Auto-Reset

Auto-Shutdown

DTT-L Series Digital Torque Testers 

User Manual

Main Menu (Continued)

Содержание DTT-L 10

Страница 1: ...oo Road Cleveland OH 44110 3898 Phone 888 486 6163 Fax 216 481 4519 Email asginfo asg jergens com Web www asg jergens com Page 1 of 15 2017 Jergens Inc All Rights Reserved Revision Date 02 19 18 DTT L...

Страница 2: ...ver Adapter 6 Usage 7 Procedure for Manual Torque Screwdrivers 7 Procedure for Power Screwdrivers 7 Battery Indicator 8 Basic Function 8 Display of Clockwise Counter Clockwise 8 Zeroing the Tester 9 C...

Страница 3: ...d or implied and all implied warranties of merchantability and fitness for a particular purpose are disclaimed and excluded from this transaction and shall not apply to the goods sold hereunder The AS...

Страница 4: ...ble 9 Volt 670 mA 90 264 VDC ASG 66619 ADC 16 Bit CPU 8 Bit Key Button 8 Buttons Unit of Measure 6 7 User Selectable Torque Units Depending on Model Mode of Measure 3 Modes Track Peak and First Peak D...

Страница 5: ...eters are supplied with the following standard items DTT L torque meter Battery charger Power adapter NOTE Rundown adapters sold separately International charger also sold separately DTT L Series Digi...

Страница 6: ...4 5 26 0 0 51 2 94 66618 1 4 Hex 25 0 80 0 2 8 9 03 66639 5 mm Hex 25 0 80 0 2 8 9 03 66634 3 8 Hex 50 0 200 0 5 65 22 6 66642 3 8 Hex 50 0 500 0 5 65 56 5 Below is a list of all rundown adapters ASG...

Страница 7: ...to be sure the readings are consistent The proper reading may be an average of several readings Procedure for Power Screwdrivers Put the appropriate rundown adapter into the unit s female 3 8 square...

Страница 8: ...tery Level 4 65V If the battery level is less than 4 6 V the Battery Empty message will be displayed and the tester will power down automatically NOTE Only use the 9V adapter charger supplied Clockwis...

Страница 9: ...m lbf in and lbf ft To change the display units press the UNIT key Each time the UNIT key is pressed it will select the next available unit until the tester returns to its original setting The DTT L...

Страница 10: ...ROW keys to move the cursor to SETTING Press ENTER To move between the submenus listed in the SETTING menu press the UP or DOWN ARROW keys to move the cursor The sub menus in the setting menu are auto...

Страница 11: ...menu page Use the UP and DOWNARROW keys to change the value Use the RIGHTARROW key to change the unit Press ZERO key to reset value to zero Press ENTER key to set new value and return to setting menu...

Страница 12: ...To access the Pass Fail menu press the MENU ESC key the display will show the main menu page Use the UP and DOWN ARROW keys to move the cursor point to SETTING Press the ENTER key and use the UP and D...

Страница 13: ...ess the MENU ESC key the display will show the main menu page Use the UP and DOWN ARROW keys to move the cursor point to MEMORY Press the ENTER key Press the UP and DOWN ARROW keys to move the cursor...

Страница 14: ...key the meter will return to the memory menu page If you select YES and press the ENTER key the meter will delete all saved records and return to the memory menu page DTT L Series Digital Torque Teste...

Страница 15: ...o access the Transducer State menu press the MENU ESC key the display will show main menu page Use the UP and DOWN ARROW keys to move the cursor point to TRANSDUCER STATE Press the ENTER key Press the...

Отзывы: