Replacing the level sensors
Tools:
8 in. crescent wrench
1. Trace the electrical leads from the tank level sensor and the tilt
shutoff sensor to the control board and remove the sensors'
connectors. Note the wiring configuration from the sensors to
their connectors. Note the mating connector located on board.
2. Note the orientation, then unscrew the level sensor from the
tank. Remove the mounting hardware from the tilt sensor.
3. Install the new sensors as required. On the tank sensor, make
sure the peaked portion of the exposed fitting labeled N.O.
(normally open) is positioned upward. Rewire and attach the
new electrical connector at the original board location.
Replacing the electric intake pump
(Figure Q)
Tools:
Pliers, 5/16 deep well socket or driver, and
a flat blade screwdriver
1. Remove the snapper type clamp from each end
of the pump by pushing its tabs in opposite
directions. Use pliers to improve clamp
manipulation. Work the tubing off each end of
the pump.
2. Loosen the green retaining screw and remove
the grounding wire from the pump.
3. Remove the two nuts which mount the pump to
the bracket.
4. Trace and disconnect the pump wiring from the
control board and the solenoid valve. Connect
the new wires at the old locations.
5. Replace the pump and reassemble by reversing steps. Make sure that the flow direction arrow on
the new pump points away from the solenoid valve.
Replacing the electronics board
(Figure R)
Tools:
1/4 open face wrench or crescent wrench, Phillips
screwdriver, and pliers
1. Remove the board mounting hardware from each of the four
corners of the control board.
2. Wire the new board by tracing the leads from the old board or by
following the wiring schematic,
Refer to Figure S.
3. Secure the new control board in each corner with the mounting
hardware.
Page 12
Figure Q - Intake Pump
Figure R - Electronics Board
Figure P - Level Sensors
Tilt Shutoff Sensor
Tank
Level Sensor