9
8.5.
FILTER INSTALLATION
Working in the reverse order, follow these steps to reinstall your filters:
8.5.1
Ultraviolet Lamp Installation:
Grasping lamp gently by end caps, align pins horizontally with slot in lamp socket and insert pins fully
into socket. Rotate the lamp in either direction approximately 90°, (1/4 turn), until the bulb locks into
place as shown in illustration 1 below.
NEVER put excessive force or use pliers on the glass or end caps as this may cause the bulb to
break causing personal injury or property Damage.
ALWAYS handle UV lamps with care as they are fragile like any other light bulb.
8.5.2
HEPA/Carbon Filter Installation:
After installing the UV lamps, place the HEPA/Carbon filter inside the unit with the white pull-tabs on
top, facing out towards you, and with its bottom edge resting on the back, bottom edge of the filtering
compartment. With your fingers only on the frame near the top, gently push filter into the housing
until it fully and firmly seats against the back of the filtering compartment as shown in illustration 2
below.
8.5.3
Washable Prefilter Installation:
Place the prefilter into the housing against the HEPA/Carbon with the same side facing out as was
before removal, while holding it in place rotate the filter retaining swivel locking tabs to secure the
filters in place as shown in illustration 3 below.
8.5.4
Front panel installation:
Place the bottom tabs of the front panel into the slots on the bottom of the housing and pivot the cover
inwards while using your thumbs to gently press inwards on the upper outer corners of the panel until
it fully seats. Release pressure and cover should now be held in place; see illustration 4 below.
1 2 3
4
9. TROUBLESHOOTING
Problems
Cause
Solution
The unit will not turn on.
1. Faulty power source.
2. Front panel not installed properly.
3. Filters not properly seated and secured.
4. Power cord damaged.
1. Confirm power outlet is working.
2. Secure Front panel.
3. Check filters for correct installation.
4. Have power cord replaced by certified technician.
No air comes out of unit or is
noisy
1. Air inlets or outlet blocked.
2. Plastic protective cover still on filters.
1. Remove any objects blocking air inlets or outlet.
2. Remove protective cover around the filters.
Filtered air coming from unit
smells unpleasant
1. The filters are dirty.
2. Plastic protective cover still on filters.
1. Clean or replace the filters.
2. Remove protective cover around the filters.
Check filter light is blinking
1. Unit has been used for 3,000 hours or
more since last timer rest.
1. Check, clean and replace filters.
2. Press and hold FAN SPEED
+
and TIMER
-
buttons
on front panel until unit chimes once to reset timer.
10. WARRANTY
STANDARD and OPTIONAL LIMITED LIFETIME WARRANTIES
All of our products are designed, manufactured and tested to the highest standards, but things do happen, which is
why we provide the following Standard Warranty on all our products, and offer an optional Limited Lifetime Warranty
on qualifying products.