The operating life of the electrodes 

 
The electrodes are made of titanium coated with a special layer of ruthenium and iridium. During the electrolysis 
this layer is consumed. In order their decrese was minimal, you should avoid 
 

 

Low content of salt (under 4 g/l) 

 

Water temperature below 10°C  

 

Low water flow  

 

Too hard water  

 

The pH level under 7.5 

 

Addition of chemicals containing metals 

 

 
Cleaning of the electrodes 
 

During the operation the electrodes are gradually polluted by  deposits from hard water which must be perodically 
removed.  The  clogging  of  the  electrodes  causes  the  output  decrease,  i.e.  at  unchanged  salt  content  the  output 
decreases (observed  on the display on the fromt panel). In this case the system must be switched off, electrodes 
taken out and for about 10 minutes plunged into the solution for the electrodes cleaning. The whity coating should 
disappear and the electrodes can be returned back. 

 

 

Maintenance 

 
Neither ASIN  Salt  2  nor  the  electrolyzer  TE13  require  any  maintenance.  However,  both  device  are  situated  in  a 
corrosive environment and therefore it is necessary to check, eventually clean the elctric connections. 
The electrolyzer must be kept in the temperare above zero, 

water inside may in no case freeze!

 

 
Ocupational safety 

 
ASIN Salt 2 may operate persons without electronic qualification.  
Removing  covers  and  exchanging  any  of  the 

machine’s  parts  is  forbidden.  To  clean  the  machine,  use  a  cloth 

dampened with water or detergent. Use ethyl alcohol to remove stubborn stains. The use of other organic solvents 
is forbidden, as well as the use of any cleaners that would cause abrasion of the surface of the plastic case or the 
front cover. 
Persons  working  with  ASIN  Salt  2  must  be  informed  that  using  the  machine  in  a  manner  not  intended  by  its 
manufacturer can render ineffective the electrical safety features of the device. 

 

Guarantee 

 
The manufacturer is liable for defects of the ASIN Salt 2 equipment and electrolytic cell for 2 years from the date of 
sale. If this date is not credibly evidenced, the guarantee period starts on the production date indicated on the pro-
duction label.  
The manufacturer is not liable for defects caused by the operation of  ASIN Salt 2 in contradiction with the manual 
as well as for defects caused by inexpert installation of the equipment. 
Before  you  call  a  maintenance  technician  to  exercise  the  guarantee  check  the  following  point  that  are  within  the 
scope of your responsibility. 
 

 

The power supply is functional  

 

The equipment is installed in accordance with the manual  

 

Water has the correct pH parameters and content of salt  

 

The electrolytic cell is clean  

 

There is a sufficient water flow through the electrolytic cell 

 

The fuse of the device is OK. 

 

!!!  WARNING !!! 

All of the chemicals used for water quality treatment are caustic. Do not allow them to come in contact with 
your  skin!  Wear  rubber  gloves  and  work  with  all  due  care  when  refilling  chemical  supplies  and  when 
changing  pump  tubes.  Stains  on  clothing  from  these  substances  will  cause  irreparable  damage!  Always 
obey  the  safety  instructions  for  the  individual  chemicals  (see  the  safety  sheets)  when  handling  them  or 