background image

 

 

ASEKO s.r.o.,  

Vídeňská 340,  25242 Vestec u Prahy

 

 

Phone 244 912 210 

Fax 244 910 800 

[email protected] 

http://www.aseko.cz 

 

 

Fig.3. The electric connection of  
 

ASIN Aqua S switch 

Connection of ASIN Aqua S 

Connection of the electrolyzer 

Connector of the conductivity transmitter 

Pressbutton for output increasing 

Pressbutton for output decreasing 

Power supply socket with the main switch and fuse 

 

Taking into operation 

 
ASIN  Salt  2  can  be  operated  either  separately  (the  electrolysis  is  started  together  with  the  filtration  plant)  or  in 
connection with the regulator ASIN Aqua S. The relevant alternative must be adjusted in ASIN Salt 2: In case of the 
separate operation the switch 1 (fig. 3) must be in the position OFF, otherwise in the position ON. 
We recommend you to put the system in operation in clean chlorinated water. 
ASIN Salt 2 only starts to produce sufficient quantities of the disinfection agent in a few hours. As for the first chlo-
rination the need of the disinfection agent is significantly higher than during stable operation, it may happen that 
ASIN Salt 2 will not achieve the required concentration of the disinfection agent. This is why we recommend you to 
chlorinate the pool water by pouring approx. 30 ml of the chlorine disinfection agent per m3 of water volume. If the 
volume of your pool is 40 m3, pour approx. 30 x 40 = 1200 ml into the swimming pool.  
Add 4 - 8 kg of salt per m3 

 

of pool water. For example: the dimensions of your swimming pool are 4 m x 10 m and 

the depth of water 1 m. It means that its volume is 4 x 10 x 1 = 40 m3. The added quantity of salt is 40 x 4 = 160 
kg. Before connecting ASIN Salt 2 to the mains you must carefully let the salt dissolve. Approx. 24 hours after 
complete dissolution check the pH value. 

In case it is lower than 7.3 (optimum is 7.5), adjust it by the addition 

of the pH+ liquid

. The inproper pH value causes the service life shortening of the electrodes. 

Now switch ASIN Salt 2 on and read its output on the left display. Depending on the pool size and output find the 
ideal running period in the table which shows the recommended output for the giveb pool volume and 8 hours ope-
ration of the filtration plant. The chlorine production depends on the salt concentration and temperature. The lower 
is temperature, the lower is the chlorine production. You can increase the output of the electrolyzer by adding more 
salt. 1 kg of salt per m3 of water will increase the output by approx. 10%. The maximum quantity of salt that you 
can use is approx. 15 kg per m3. Exceeding this limit concentration would cause overloading of the feeding part of 
ASIN Salt 2. To avoid this, ASIN Salt 2 is equipped with automatic monitoring of the maximum current. In case of 
overloading it gets disconnected automatically. Before switching the system on again you must dilute the pool wa-
ter. 
Never use salt concentrations lower than 2 g per litre - it significantly reduces the operating life of the electrodes. 
Never use the lower concentartion than 4 g/l 

– it decreses substancially the operating life of the electrodes. 

 
 

g Cl / hour 

Pool volume (m3) 

25 

13 

40 

18 

55 

23 

70 

 
 
Table I. The relation between the output, chlorine production and pool volume 
 
After checking the chlorine content in the swimming pool reduce or increase the running period accordingly. 
You  should  realize  that  the  specified  figures  represent  average  values.  The  need  of  disinfection  is  materially 

Отзывы: