current inside temperature

Rotary button to show/change 
preset value

C1 

LED "air flow OK" 

C2 

LED "air flow error" 

D1 

LED "filter OK" –

D2 

LED "filter error" 

4. FUNCTION

4.1.  GENERAL NOTES

CAUTION:

The drawer is to be kept close. The inbuilt magnets will hold the drawer close to the the housing. 

For best operation of the cabinet make sure the time in which the drawer is open stays as short as 

possible!

• The inside temperature fluctuates around the value set. This fluctuation is not caused to defect. 

The control unit has to detect a fluctuation to go active.

• The refrigerator defrosts need-based, even if the temperatures in the cabinet and the vaporizer are 

at factory-made parameters. The deforsting and connected, momentary temperature increse of the 
cabiinet interior have no effect on the temperature of the stored fluids, because these react much 
more inactively to temperature variations. The defrost process is audibly through a loud click and is 
concluded through adjusted temperature values again.

4.2.  SHOW AND CHANGE THE PRESET VALUE

2

10.0

1

>2 sec

 

2

8.5

2

 

2

7.0

3

2

7.0

<0,5 sec

4

 

2

10.0

5

 

Within the menu display chan-

ges between preset value and 

current inside temperature.

CAUTION:

After several seconds without action the menu will be left automatically. According to the surrounding 

conditions more parameters can be adjusted by our Customer Service Dept.

5. FAULT

5.1.  OPERATING DISPLAYS

EVENT

7-digit-display

LED (D1) 

„filter OK“

LED (D2) 

„filter error“

LED (C1)

„air flow OK“

LED (C2)

„air flow error“

aoustic alarm

fan, evaporator, 

compressor

Self-test

„888“

All LEDs light up briefly in succession, followed by a short beep

Only fan on

Figaro stabilisation

X

Alternating until 

stabilisation time reached

Only fan on

Normal operation

Interior temperature

X

X

Fan on, remainder 
according to 
function

Setting of nominal value for 
interior temperature

“SP” and nominal 
value alternating

LED depending on the state of the equipment which is  

to be monitored

Fan on, remainder 
according to 
function

Operating duration >11 
months

Interior temperature

Flashing

X

Fan on, remainder 
according to 
function

Operating duration >12 
months

Interior temperature

X

X

Alarm sound 
every 60 
minutes

Fan on, remainder 
according to 
function

5.2.  FAULTS AND ACTIONS 

FAULT

PROBLEM – ACTION

NOTE - please observe!

A

•  7-digit display is off
•  LED air flow (C2): short flash 

every 20 seconds

•  Signal sound every 60 

seconds

Problem

: Power failure 

Actions:

 Check power supply at the mains socket and 

restore if necessary
OR
1.  Unplug the mains plug.
2.  Check the two fine-wire fuses in the C14 socket
3.  Replace them by identical fuses if necessary.

In the case of a power failure lasting longer than one 
hour, the internal battery (emergency power supply) is 
switched off to protect it against total discharge. After the 
battery switches off the display and signal sound are also 
switched off! After the power is restored the refrigera-
ting underbench cabinet starts normal operation again 
automatically. The battery is charged up again.

B

•  Air flow alarm (C2) lights up
•  Warning sound 30 seconds

Problem

: Exhaust air flow rate has fallen below the mini-

mum required rate (e.g. filter clogged, fire damper closed)

Actions:

1.  Press button to end the warning sound
2.  Unplug the mains plug
3.  Have the necessary volumetric flow restored by a 

ventilation expert

Once the exhaust is working again, close the drawer and 
plug the mains plug into the socket again.

If the battery was switched off, the refrigerating under-
bench cabinet performs a self-test once again.

C

•  "rSF" on the display

Problem:

 Preset nominal temperature value was not 

reached.

Action

: Increase the nominal temperature value (see 4.2)

Refer to Errors if this does not solve the problem

:    

D

“rSF” appears on the display as soon as the nominal tem-
perature value has not been reached within a preset time 
and the compressor has been switched off. In order to 
prevent this, ensure during the initial commissioning that 
the refrigerating underbench cabinet is opened as infre-
quently as possible. Excessively high ambient temperature 
and humidity can also lead to this error. The nominal 
temperature value must then also be increased.

D

•  "rSF" on the display

Problem: 

The evaporator is iced up. The nominal 

temperature value was not reached.

Action:

1.  Unplug the mains plug. 
2.  The evaporator can thaw out.
3.  Disconnect the device from the mains for at least  
  24 hours.
4.  After that, plug the mains plug in again. Increase  
  the nominal temperature value (see 3.2), so that  
  this can be reached and icing-up can be avoided

Under standard conditions the icing-up of the evaporator 
is not possible. Make sure that you select the nominal 
temperature value on the basis of the external environ-
ment in such a way that it is possible to reach it.

E

•  "AL1" on the display

Problem: 

Temperature in the interior is higher than max.

Action: 

1. Close the drawer if it is open!

2. Check the compressor. If it is off, contact 

CUSTOMER 

SERVICE!

See point 9!

Содержание UB90.060.110.KU.S

Страница 1: ...tie für Ihren SL LINE Sicherheitsschrank 5 YEARS WARRANTY Upon conclusion of an asecos service and maintenance agreement BasicPlus tariff with a fixed term of 5 years you will get a warranty extension for a maximum of 5 years for your SL LINE safety storage cabinet Weitere Informationen zu unseren Garantieleistungen finden Sie unter www asecos com service leistungen For detailed information about ...

Страница 2: ...ßeren Gefäße eingestellt werden als das Volumen der Bodenauffangwanne fassen kann austretende Gefahrstoffe sind sofort aufzunehmen und zu entfernen Überprüfen Sie vor Einlagerung die Beständigkeit der Schrankoberfläche gegen die Chemikalie Vor der ersten Inbetriebnahme ist der Sicherheitsschrank vom Nutzer auf eventuelle Schäden zu untersuchen Aufstell und Umgebungsbedingungen 0 35 C 30 70 1 2 GEW...

Страница 3: ...ken alle 20 Sekunden Signalton alle 60 Sekunden Problem Stromausfall liegt vor Maßnahmen Stromversorgung an der Netzsteckdose überprüfen und ggf wiederherstellen ODER 1 Ziehen Sie den Netzstecker ab 2 Überprüfen Sie die beiden Feinsicherungen im Kaltgeräteeinbaustecker 3 Tauschen Sie diese gegebenenfalls gegen identische aus Bei einem Netzausfall länger als eine Stunde wird der interne Akku Notstr...

Страница 4: ...al erfolgen Wenden Sie sich dazu an unsere Service Abteilung 8 TECHNISCHE DATEN Stromanschluss 230 V Frequenz 50 60 Hz Nennstrom 2 A Anlaufstrom 6 8 A 8 1 A Leistunsaufnahme Standby 7 2 W Betrieb 247 W cos φ 0 6 Abwärme ca 1 kw 9 SICHERHEITSTECHNISCHE ÜBERPRÜFUNG KUNDENSERVICE Die Kühlunterbauschrank ist als sicherheitstechnische Anlage gemäß 4 Abs 3 Arbeitsstätten verordnung 10 Betriebssicherheit...

Страница 5: ...aterials are to be collected immediately and removed Before storing such materials check that the cabinet s surface is resistant to the chemicals The storage of corrosive liquids or gases can affect the function of the shut off equipment for the air supply and exhaust Before the initial commissioning the safety storage cabinet is to be examined by the user for possible damage Set up requirements 0...

Страница 6: ...h every 20 seconds Signal sound every 60 seconds Problem Power failure Actions Check power supply at the mains socket and restore if necessary OR 1 Unplug the mains plug 2 Check the two fine wire fuses in the C14 socket 3 Replace them by identical fuses if necessary In the case of a power failure lasting longer than one hour the internal battery emergency power supply is switched off to protect it...

Страница 7: ...N The middle pin of the contact is not configured The contact must be connec ted as shown in the illustra tion CUSTOMER 7 REPAIR CAUTION Before every repair the power supply must be disconnected Repairs may be carried out only by trained specialists In the case of damage the device is to be repaired or is to be exchaged through the manufacterer 8 TECHNICAL DATA Voltage 230 V Frequency 50 60 Hz Rat...

Страница 8: ......

Страница 9: ...1616 ...

Отзывы: