Ascon Tecnologic - ATT1/ATT1-I - ENGINEERING MANUAL - PAG. 2

INSTALLATION INFORMATION

Dimensions

45

23

2

6

4

3

1

Vdc

+

mA

A

B

B1

A1

Tc

NFC

-

+

PWR

7..30Vdc

5

Out

Electrical connections

Carry out the electrical wiring by connecting only one wire to each 

terminal and according to the following diagrams:

Output

2

6

4

3

1

Vdc

+

mA

A

B

B1

A1

Tc

NFC

-

+

PWR

7..30Vdc

5

Out

+

Output

terminal

Output

terminal

Pt100, Pt1000 and Ni100 Sensors

2

6

4

3

1

Vdc

+

mA

A

B

B1

A1

Tc

NFC

-

+

PWR

7..30Vdc

5

Out

2

6

4

3

1

Vdc

+

mA

A

B

B1

A1

Tc

NFC

-

+

PWR

7..30Vdc

5

Out

2

6

4

3

1

Vdc

+

mA

A

B

B1

A1

Tc

NFC

-

+

PWR

7..30Vdc

5

Out

2 wires

3 wires

4 wires

B

A

B B1

A

A1

B B1

A

Note: The PT1000 sensors must be connected in 2 wires mode.

TC K, S, R, J, T, N, B, E Sensors

2

6

4

3

1

Vdc

+

mA

A

B

B1

A1

Tc

NFC

-

+

PWR

7..30Vdc

5

Out

2

6

4

3

1

Vdc

+

mA

A

B

B1

A1

Tc

NFC

-

+

PWR

7..30Vdc

5

Out

2

6

4

3

1

Vdc

+

mA

A

B

B1

A1

Tc

NFC

-

+

PWR

7..30Vdc

5

Out

+

+

+

+

+

+

+

Differential measure

between 2 TC of the

same type

Note:

 

Exclude the CJ 

 

compensation

+

+

Average temperature measure

between multiple TCs of the 

same type

10... 400 

W

 and 10... 4000 

Potentiometer

2

6

4

3

1

Vdc

+

mA

A

B

B1

A1

Tc

NFC

-

+

PWR

7..30Vdc

5

Out

2

6

4

3

1

Vdc

+

mA

A

B

B1

A1

Tc

NFC

-

+

PWR

7..30Vdc

5

Out

2

6

4

3

1

Vdc

+

mA

A

B

B1

A1

Tc

NFC

-

+

PWR

7..30Vdc

5

Out

2 wires

3 wires

4 wires

B

A

B

A

B

A

B1

B1

A1

Note: The 4000 

W

 potentiometer must be connected in 2 wires mode.

Voltage input

2

6

4

3

1

Vdc

+

mA

A

B

B1

A1

Tc

NFC

-

+

PWR

7..30Vdc

5

Out

+

TECHNICAL CHARACTERISTICS (@ 20°C)

General specifications

Insulation voltage: 1 kV AC for 1 minute (ATT1-I model only);
RTD excitation current: < 200 

m

A;

RTD maximum wire resistance: 20 

Ω

 per wire;

Cold junction accuracy: ±0.5°C;
Cold junction drift: 0.05°C/°C;
Voltage operating range: 7... 30 Vdc;
Current output: 4... 20 mA (2 wires);
Output resolution: 2 

m

A;

Over-range output value: +5°C;
Under-range output value: -5°C;
Failure output value: Selectable between 21 mA, 3.8 mA or any 

other value;
Rejection: 50... 60 Hz;
Temperature drift: < 150 ppm;
Sampling time: 300 ms;
Response time (10%input, 90% output):

 - With no filters: 400 ms,
 - With medium filter: 2 s,
 - With strong filter: 6 s;

Protection: IP 20;
Compliance: CE, EN 61326-1;
Operating temperature: -40... +85°C;
Humidity: 30... 90% @ 40°C (with no condensation);
Storage temperature: -40... +105°C;
Connections: Screw terminals;
Enclosure: PA66;
Dimensions: Ø45 mm, thickness 23 mm.

Отзывы: