System Installation
On Site Paging System

4

bus without modem must not exceed 500 metres. If the SP-bus is 1-way, the length can be 
increased to max 3 km with bus amplifier T938BA.

D-bus    3 km

Terminal 
Transmitter

Slave 
Driver

Slave 
Transmitter

Central 
Unit

SP-bus    500 m

Figure 2. Max D- and SP-bus length.

In HF installations a Power Divider is required between every transmitter for driving the 
Slave Transmitters, and in UHF systems a Slave Driver is used between the Terminal 
Transmitter and the first Slave Transmitter in series. The Slave transmitters have one output 
and they can be connected in series or used as line amplifiers. However, in most cases it is 
also advisable to connect an antenna to the line amplifier, especially in speech systems 
where speech quality depends directly on coverage.

Slave transmitters are connected with coaxial cable RG-8 or RG-213 with a maximum 
length of 700 metres. Distances exceeding this require line amplifiers. A separate power 
supply feeds the slave, but if the slave is mounted close to other units the power can be 
taken from one of them.

D-bus   3 km

Terminal 
Transmitter

Slave 
Driver

Slave 
Transmitter

Central 
Unit

SP-bus   500 m

 700 m

Slave 
Transmitter

 700 m

Power 

Divider

 700 m

Power 

Divider

 700 m

D-bus   3 km

Terminal 
Transmitter

Slave 
Transmitter

Central 
Unit

SP-bus   500 m

Slave 
Transmitter

HF

UHF

Slave 
Transmitter

 700 m

Slave 
Transmitter

 700 m

Figure 3. Max coaxial cable length.

Equipment for Slave Transmitters

• Power Divider MPT-50, with one output used in HF installations.

• Slave Driver U952DR, with two outputs used in UHF installations.

Содержание T942PX

Страница 1: ...TD 90227GB 2006 09 18 Ver C System Installation On Site Paging System...

Страница 2: ...8 Extended Wiring Lengths 3 2 Telephone and PBX Connection 3 3 Transmitters 3 3 1 Frequency Locked Transmitters 5 3 2 Without Modem to Transmitters 5 3 3 With Modem to Transmitters 6 4 Receivers 7 5 A...

Страница 3: ...ic fields vibration or rapid temperature changes The procedure for the installation of each unit is described in the installation guide for the respective unit 1 1 OSP On Site Paging PBX Private Branc...

Страница 4: ...C bus is used for communication between different installations i e between two or more Central Units D bus transmits pagings in transmit format from the Central Unit to one or several Terminal Trans...

Страница 5: ...n leased lines 2 Telephone and PBX Connection A telephone set or a PBX can be used as control unit via a PBX Interface module The PBX Interface accepts both dialling pulses and DTMF tones and can be c...

Страница 6: ...connect an antenna to the line amplifier especially in speech systems where speech quality depends directly on coverage Slave transmitters are connected with coaxial cable RG 8 or RG 213 with a maxim...

Страница 7: ...Terminal Transmitter s circuit board Reference Module T938RM with drive circuits for FL bus controlled by the Central Unit Bus Amplifier T938BA T938RM without ref tone generator with drive circuits f...

Страница 8: ...y The transmitter code on the D bus is always generated by the Central Unit Be sure that the same number of modem pairs are used between the Central Unit and each Terminal transmitter Several Terminal...

Страница 9: ...eech Modem Modem Compensator Fixed Receiver Terminal Transmitter Data Modem Receiver Interface Data Modem Figure 6 Terminal site with SP bus 4 Receivers Talk back Receivers are always connected to a R...

Страница 10: ...h as ground plane dipole and helix antennas but the choice of type should be made to suit the actual site In some cases other types of antennas may be required due to the terrain or climatic condition...

Страница 11: ...ground plane antenna for mounting on a mast The antenna is frequency adjusted by cutting the fibre glass elements to the correct length according to the diagram that is delivered with the antenna The...

Страница 12: ...a Location An outdoor antenna should be located as centrally and unobstructed as possible within the designed coverage area The antenna must not be placed near metal clad chimneys or similar structure...

Страница 13: ...ne location The power supply is connected to screw terminals on one of the units and then connected in series to the other units The wiring from the power supply must be dimensioned so that the voltag...

Страница 14: ...ng interface T966CI are powered via the 12 conductor cable Charging racks not connected to the interface must be powered separately Linear power supplies are generally recommended specially for the tr...

Страница 15: ...he hex digits 0 F OFF ON Hex 0 OFF ON Hex 8 Hex 1 Hex 9 Hex 2 Hex A Hex 3 Hex B Hex 4 Hex C Hex 5 Hex D Hex 6 Hex E Hex 7 Hex F 1 OFF ON Hex 0 Hex address 00 8 Hex 0 1 OFF ON Hex 1 Hex address 01 8 He...

Страница 16: ...tween the transmitters but cannot be used in speech systems Address Register 0 0 0 1 0 2 0 3 0 4 1 0 2 0 T942C T942PX T840IU T966CI U952T U952T U952T Attic head office Exchange room head office Exchan...

Страница 17: ...age area by transmitting pagings with speech if applicable and compare with the expected coverage area If coverage is not as expected check the installation and location of the antenna If this does no...

Страница 18: ...pled This must be considered when planning a combined system installation T850 U952 T840 Figure 17 An example of an installation that cannot function due to grounding Both transmitters are mounted on...

Отзывы: