90°
2a
1a
0,5 x 3 mm
5
0,5 x 3 mm
90°
6
4
2
3
1
90°
9
MOUNTING ON CYLINDERS WITH GROOVES - TYPES PEC,PES:
1 - Turn the knurled nut manually by
90° so that it is retracted inside.
A
A
B
C
2 - Engage the detector into the
groove.
3 - Press the detector down into the
groove.
4 - Position the detector at the measur-
ing point.
Note:
To control end of stroke positions
observe recommendations given op-
posite.
B
5 - Hold the detector in place and
tighten the screw. This causes the
knurled nut to rotate.
- Make sure the detector is correctly
placed in the groove (perpendicular
to the groove’s axis).
6 - Block the detector on the cylinder.
Maximum screw tightening torque:
0.14 N.m
C
PREPARATION
INSTALLATION / ADJUSTMENT
TIGHTENING
0,14 N.m
1a- Loosen the screw. This causes the
knurled nut to rotate by 90° and be
retracted inside.
2a-
Continue
loosening the screw
until the knurled nut is in the bot-
tom position and
the bottom end
of the screw is fl ush with the
bottom of the nut
(see drawing
opposite).
A
A
PREPARATION
1st ASSEMBLY
2nd ASSEMBLY
Proceed with Installation, adjustment and tightening as described in phases B and C (steps 2 to 6) above.