Specifications

Operating Voltage

30 - 200 VDC

Clamping Voltage

33 - 211 VDC

Operating Current

7 Amp

Peak Surge Current

400 A

Operating Frequency

DC - 30 MHz

Series Impedance

<0.10 Ohms (<0.20 Ohms/pair)

SPD Technology

Silicon Avalanche Diode (SAD)

Modes of Protection

L-G

Connection Type

Wire Clamp Terminals

Operating Temperature

-40°C to +60°C

Dimensions (in / mm)

2.0 x 3.0 x 1.5 in.

[50.8 x 76.2 x 38.1 mm.]

Weight (lb / kg)

0.15 lb [0.07 kg]

Certifications

UL 497B

Limited warranty

5 Years

ASCO Model 146 (Edco PLP-S Series)

Surge Protective Device (SPD)

Содержание 146

Страница 1: ...Surge Protective Devices Installation Operation Manual Model 146 ...

Страница 2: ...symbol It is used to alert you to potential personal injury hazards Obey all safety messages that follow this symbol to avoid possible injury or death DANGER DANGER indicates a hazardous situation which if not avoided will result in death or serious injury WARNING WARNING indicates a hazardous situation which if not avoided could result in death or serious injury CAUTION CAUTION indicates a hazard...

Страница 3: ...ipment This equipment must be effectively grounded per all applicable codes Use an equipment grounding conductor to connect this equipment to the power system ground Do not supply more than 7A AC to Surge Protective Device Confirm that the Surge Protective Device voltage rating on the module or nameplate label is not less than the operating voltage This equipment must be installed indoor on loop c...

Страница 4: ...ing two screws or bolts size 6 to 10 install the unit and cables as close as possible to the protected equipment and secure 4 Connect a 12 16 AWG ground wire using a crimp on ring terminal from the SPD ground terminal to the equipment chassis ground 5 Complete the circuit by connecting cables from the load of the SPD to the protected equipment 6 Check that all connections are secure Remove all too...

Страница 5: ...oltage 33 211 VDC Operating Current 7 Amp Peak Surge Current 400 A Operating Frequency DC 30 MHz Series Impedance 0 10 Ohms 0 20 Ohms pair SPD Technology Silicon Avalanche Diode SAD Modes of Protection L G Connection Type Wire Clamp Terminals Operating Temperature 40 C to 60 C Dimensions in mm 2 0 x 3 0 x 1 5 in 50 8 x 76 2 x 38 1 mm Weight lb kg 0 15 lb 0 07 kg Certifications UL 497B Limited warr...

Страница 6: ...1 888 778 2733 for technical assistance MODEL Former Model Name OPERATING VOLTAGE CLAMPING VOLTAGE 146D033S400SN4N0 Edco PLP 42S 30 VDC 33 VDC 146D067S400SN4N0 Edco PLP 43S 60 VDC 67 VDC 146D150S400SN4N0 Edco PLP 44S 140 VDC 150 VDC 146D211S400SN4N0 Edco PLP 45S 200 VDC 211 VDC Model Cross Reference ASCO Model 146 Edco PLP S Series Surge Protective Device SPD ...

Страница 7: ... All Rights Reserved 7 IO 75016 01 2020 For access to self service tools and chat support visit se com us en work support or call 1 888 778 2733 for technical assistance ASCO Model 146 Edco PLP S Series Surge Protective Device SPD ...

Страница 8: ... en work support 1 888 778 2733 While every precaution has been taken to ensure accuracy and completeness in this literature Schneider Electric assumes no responsibility and disclaims all liability for damages resulting from use of this information or for any errors or omissions ...

Отзывы: