background image

© 2020 ASCO Power Technologies. All Rights Reserved

2

IO-75016

01/2020

For access to self-service tools and chat support visit se.com/us/en/work/support  or call 1-888-778-2733 for technical assistance

ASCO Model 146 (Edco PLP-S Series)

Surge Protective Device (SPD) 

 
 

 

 

Safety Information 

 

  Important Information

 

   

Read these instructions carefully and look at the equipment to become 

familiar with the device before trying to install, operate, service or maintain it. 

The following special messages may appear throughout this bulletin or on the 

equipment to warn of potential hazards or to call attention to information that 

clarifies or simplifies a procedure. 

 

   

The addition of either symbol to a “Danger” or “Warning” safety label 

indicates that an electrical hazard exists which will result in personal 

injury if the instructions are not followed. 

 

   

This is the safety alert symbol. It is used to alert you to potential 

personal injury hazards. Obey all safety messages that follow this 

symbol to avoid possible injury or death. 

 

 

 

DANGER

 

DANGER

 indicates a hazardous situation which, if not avoided,  

will result in

 death or serious injury. 

 

 

WARNING

 

WARNING

 indicates a hazardous situation which, if not avoided,  

could result in

 death or serious injury. 

 

 

CAUTION

 

CAUTION

 indicates a hazardous situation which, if not avoided,  

could result in

 minor or moderate injury. 

 

NOTICE

NOTICE is used to address practices not related to physical injury. The safety 

alert symbol shall not be used with this signal word. 

 

 

 

 

  Please Note 

 

   

Electrical equipment should be installed, operated, serviced, and maintained only 

by qualified personnel. No responsibility is assumed by ASCO Power Technologies 

for any consequences arising out of the use of this material. 

A qualified person is one who has skills and knowledge related to the 

construction, installation, and operation of electrical equipment and has received 

safety training to recognize and avoid the hazards involved. 

 

 

Содержание 146

Страница 1: ...Surge Protective Devices Installation Operation Manual Model 146 ...

Страница 2: ...symbol It is used to alert you to potential personal injury hazards Obey all safety messages that follow this symbol to avoid possible injury or death DANGER DANGER indicates a hazardous situation which if not avoided will result in death or serious injury WARNING WARNING indicates a hazardous situation which if not avoided could result in death or serious injury CAUTION CAUTION indicates a hazard...

Страница 3: ...ipment This equipment must be effectively grounded per all applicable codes Use an equipment grounding conductor to connect this equipment to the power system ground Do not supply more than 7A AC to Surge Protective Device Confirm that the Surge Protective Device voltage rating on the module or nameplate label is not less than the operating voltage This equipment must be installed indoor on loop c...

Страница 4: ...ing two screws or bolts size 6 to 10 install the unit and cables as close as possible to the protected equipment and secure 4 Connect a 12 16 AWG ground wire using a crimp on ring terminal from the SPD ground terminal to the equipment chassis ground 5 Complete the circuit by connecting cables from the load of the SPD to the protected equipment 6 Check that all connections are secure Remove all too...

Страница 5: ...oltage 33 211 VDC Operating Current 7 Amp Peak Surge Current 400 A Operating Frequency DC 30 MHz Series Impedance 0 10 Ohms 0 20 Ohms pair SPD Technology Silicon Avalanche Diode SAD Modes of Protection L G Connection Type Wire Clamp Terminals Operating Temperature 40 C to 60 C Dimensions in mm 2 0 x 3 0 x 1 5 in 50 8 x 76 2 x 38 1 mm Weight lb kg 0 15 lb 0 07 kg Certifications UL 497B Limited warr...

Страница 6: ...1 888 778 2733 for technical assistance MODEL Former Model Name OPERATING VOLTAGE CLAMPING VOLTAGE 146D033S400SN4N0 Edco PLP 42S 30 VDC 33 VDC 146D067S400SN4N0 Edco PLP 43S 60 VDC 67 VDC 146D150S400SN4N0 Edco PLP 44S 140 VDC 150 VDC 146D211S400SN4N0 Edco PLP 45S 200 VDC 211 VDC Model Cross Reference ASCO Model 146 Edco PLP S Series Surge Protective Device SPD ...