background image

© 2020 ASCO Power Technologies. All Rights Reserved

2

IO-75024

01/2020

For access to self-service tools and chat support visit se.com/us/en/work/support  or call 1-888-778-2733 for technical assistance

Model 159 (Edco HVCP-48)

Surge Protective Device (SPD) 

 
 

 

 

Safety Information 

 

  Important Information

 

   

Read these instructions carefully and look at the equipment to become 

familiar with the device before trying to install, operate, service or maintain it. 

The following special messages may appear throughout this bulletin or on the 

equipment to warn of potential hazards or to call attention to information that 

clarifies or simplifies a procedure. 

 

   

The addition of either symbol to a “Danger” or “Warning” safety label 

indicates that an electrical hazard exists which will result in personal 

injury if the instructions are not followed. 

 

   

This is the safety alert symbol. It is used to alert you to potential 

personal injury hazards. Obey all safety messages that follow this 

symbol to avoid possible injury or death. 

 

 

 

DANGER

 

DANGER

 indicates a hazardous situation which, if not avoided,  

will result in

 death or serious injury. 

 

 

WARNING

 

WARNING

 indicates a hazardous situation which, if not avoided,  

could result in

 death or serious injury. 

 

 

CAUTION

 

CAUTION

 indicates a hazardous situation which, if not avoided,  

could result in

 minor or moderate injury. 

 

NOTICE

NOTICE is used to address practices not related to physical injury. The safety 

alert symbol shall not be used with this signal word. 

 

 

 

 

  Please Note 

 

   

Electrical equipment should be installed, operated, serviced, and maintained only 

by qualified personnel. No responsibility is assumed by ASCO Power Technologies 

for any consequences arising out of the use of this material. 

A qualified person is one who has skills and knowledge related to the 

construction, installation, and operation of electrical equipment and has received 

safety training to recognize and avoid the hazards involved. 

 

 

Содержание 159

Страница 1: ...Surge Protective Devices Installation Operation Manual Model 159 ...

Страница 2: ...l It is used to alert you to potential personal injury hazards Obey all safety messages that follow this symbol to avoid possible injury or death DANGER DANGER indicates a hazardous situation which if not avoided will result in death or serious injury WARNING WARNING indicates a hazardous situation which if not avoided could result in death or serious injury CAUTION CAUTION indicates a hazardous s...

Страница 3: ...ated voltage sensing device to confirm power is off Replace all devices doors and covers before turning on power to this equipment This equipment must be effectively grounded per all applicable codes Use an equipment grounding conductor to connect this equipment to the power system ground Confirm that the Surge Protective Device voltage rating on the module or nameplate label is not less than the ...

Страница 4: ...eld and protected terminal plugs on the device 0 28 0 31 inches 4 Connect power wire from field side to the field side terminal on device marked VS and GND for the ground 5 Connect data wiring from field to the field side of device marked SDIO and SDIO 6 Connect video wire from field to the field side of device marked Video and Video 7 Connect protected equipment wiring to all corresponding termin...

Страница 5: ...ssis SDIO SDIO GND VS OUT VIDEO IN VIDEO HVCP 48 BNC DATA 15V VIDEO 2V WKYR R Made in Mexico DC 68V UL Breakdown Voltage LISTED 4S37 ISOLATED LOOP CIRCUIT PROTECTOR SDIO SDIO GND VS FIELD PROTECTED GND Chassis SDIO SDIO GND VS OUT VIDEO IN VIDEO HVCP 48 BNC DATA 15V VIDEO 2V WKYR R Made in Mexico DC 68V UL Breakdown Voltage LISTED 4S37 ISOLATED LOOP CIRCUIT PROTECTOR FIELD PROTECTED SDIO SDIO VIDE...

Страница 6: ... SPD Technology GDT SAD Series Element Connection Type 5 08mm Terminal Block Plug Video Clamping Voltage 2 VDC Peak Surge Current 10 kA 8 x 20µs SPD Technology GDT SAD Series Element Connection Type Female BNC Jack or 5 08mm Terminal Block Plug Physical Data Ground Wire in mm 12 AWG 36 0 in 914 4 mm Long Terminal Wire Range 28 12 AWG Wiring Terminal Torque 4 5 LB in Wiring Terminal Strip Length in...

Страница 7: ...eference MODEL Former Model Name APPLICATION 159D070S10KAN6N0 Edco HVCP 48 Analog Camera 159D070S10KAN6J0 Edco HVCP 48 4X Analog Camera wtih NEMA 4X Enclosure 159D070S10KANBN0 Edco HVCP 48 BNC BNC Video Hardwire Power and Data 159D070S10KANBJ0 Edco HVCP 48 BNC 4X BNC Video Hardwire Power and Data with NEMA 4X Enclosure ACCESSORY HVDIN 11852KIT DIN Mounting Kit Model 159 Edco HVCP 48 Surge Protecti...

Страница 8: ... en work support 1 888 778 2733 While every precaution has been taken to ensure accuracy and completeness in this literature Schneider Electric assumes no responsibility and disclaims all liability for damages resulting from use of this information or for any errors or omissions ...

Отзывы: