background image

 

 

RQS Document Number: RQS.1010 Modified 16/02/2018 

37 EXPORT STREET 

LYTTON Q 4178  

PHONE: 1800 807 604                                                                                        

FAX: 1800 807 609 

P a g e   1 

 

 

RainPro RM4000-3 Rain to Mains Backup System 

Installation Guide & Owners Information 

FOR MODELS: RM4000 – RM5000 – RM6000 – RM7000  

** Please leave this guide in a safe place for the owner ** 

 

Содержание RainPro RM4000-3

Страница 1: ...7 EXPORT STREET LYTTON Q 4178 PHONE 1800 807 604 FAX 1800 807 609 P a g e 1 RainPro RM4000 3 Rain to Mains Backup System Installation Guide Owners Information FOR MODELS RM4000 RM5000 RM6000 RM7000 Please leave this guide in a safe place for the owner ...

Страница 2: ...p with float switch it will stay off until the tank fills again 10 If it is dry for a long time no rain it is best to turn the power off to the pump at the power outlet 11 External Pumps MUST be fitted with a Y Strainer between the pump and the tank and this needs to be flushed periodically if it blocks up it is not a warranty problem 12 Sometimes even after rain there might be an air pocket in th...

Страница 3: ...ner between the tank and the pump so any particles cannot clog or cause malfunction of the pump pump controller non return valves toilet cisterns washing machines and other fixtures and plumbing fittings A Y Strainer is usually included in the kit but even if it is not included the installer must obtain and fit it NO WARRANTY APPLIES IF NO Y STRAINER OR PREFILTER IS FITTED Step 3 Priming the pump ...

Страница 4: ... of rainwater is required then this could be taken off between the pump and RM4000 3 valve assembly to avoid Townwater use on the garden ensure compliance with Government Local Government and Plumbing Regulations first Important Work on the mains supply must be in accordance with the relevant plumbing code or standard and performed by a licensed plumber Step 11 Connect the supply line to house to ...

Страница 5: ... pump Pipe is sized appropriately for the application diameter and length The installation is constructed so the pump can be easily removed or replaced If applicable The pump is installed in accordance with National Local Plumbing Regulations The Electrical Supply cable of the pump is plugged into a Power Outlet that is in accordance with the current standard of Electrical Safety Regulations AS NZ...

Страница 6: ...r is BELOW the pump this will not work Once nut is done up tight press the reset button on the pressure controller and hold it for a few seconds until pump runs on its own The pump will run until all the pipe work has been pressurized then automatically switch off The pump will start again once line pressure drops which occurs when a tap is turned on NOTE you might need to turn the Townwater suppl...

Страница 7: ...ail sales ascento com au Please be aware that if our field service agent attends to your system and finds it is not a warranty problem the applicable charges must be paid by you For pumps out of warranty please contact a local pump specialist search your browser for Pump Repairs OPERATING AND MAINTENANCE INSTRUCTIONS 1 OPERATING No further action is needed once the system is installed it will oper...

Страница 8: ...y us must be constructed to allow the owner to easily remove them for servicing and to easily remove them for replacement warranty replacement or upgrading The installation must NOT be constructed in such a manner that specialized tools or paid tradespersons or external paid contractors are required to be engaged in order to remove and or replace and or refit the pump therefore the installer must ...

Страница 9: ...tance is too high Reduce distance or upgrade to a larger pump Pump runs and does not stop or runs when no taps in use Leak in pipe work Check also for leaking toilet cisterns place paper on back wall of toilet pan to check for leaking cistern or underground leaks look for wet soil muddy areas grass growing well Pump Controller Fault Press Restart If that does not help then turn the power off and o...

Страница 10: ... Motor runs for A short time then stops Pump impeller is partially clogged with particles causing motor to run slow and overload Disassemble pump and clean Motor stator may be overheating Ensure there is good ventilation for the motor have checked by a licensed electrician or call 1800 807 604 Seek advice regarding larger pump size If after checking all of the above and the fault continues CALL 18...