background image

  

 

 

 

 

ACT AT5200 
FTTX Multiport 
EDFA 

 

 

Quick Reference 
Guide 

 
Revision H 

Содержание AT5200 FTTX EDFA

Страница 1: ...ACT AT5200 FTTX Multiport EDFA Quick Reference Guide Revision H...

Страница 2: ...forbidden This document is produced to assist professional and properly trained personnel with installation and maintenance issues for the product The capabilities system requirements and or compatib...

Страница 3: ...ion 9 3 3 Power and Cooling Requirements 9 3 4 Module Installation and Adjustment 10 3 5 Front Panel Layout Layout May Vary 11 3 6 Rear Panel Layouts 12 4 Technical Description 13 4 1 Overview 13 4 2...

Страница 4: ...optical connectors when not in use The typical connectors fitted are SC APC 8 Note 8 angle polished connectors must be used Cleaning Use only a damp cloth for cleaning the front panel Use a soft dry...

Страница 5: ...up to 16 output ports in 1RU setting and 64 output ports in 2RU setting Combined with our AT5000 1550nm direct or externally modulated laser transmitter MSOs can quickly deploy and activate advanced...

Страница 6: ...AT5200 FTTX Multiport EDFA Solutions Provider for FTTx RFoG and HFC www ascentcomtec com Page 6 of 29 Application Diagram...

Страница 7: ...Insertion Loss Transmission band 0 8dB Reflection band 0 6dB Polarization Dependence Loss dB 0 1 Polarization Dependence Gain dB 0 4 Polarization Mode Dispersion ps 0 1 Input Output Isolation dB 40 Ec...

Страница 8: ...port EDFA Solutions Provider for FTTx RFoG and HFC www ascentcomtec com Page 8 of 29 The maximum output power per port is 26dBm Output power is measured after WDM Contact ACT Sales Representative for...

Страница 9: ...n and the system will recover automatically The unit should be located in an environment not exceeding a temperature range from 0 to 50 C The internal temperature should never reach 70 C If the temper...

Страница 10: ...rts to the system Always place protective dust caps on all optical ports when not in use Connect the optical input signal to the input port of the EDFA Ensure the input optical power is within the ran...

Страница 11: ...aking selections with the user interface ENT Button Start the menu by pushing ENT first refer to 5 2 4 5 6 LASER ON OFF OPT IN Dual OPT IN optional OPT OUT Key switch for laser activation Optical inpu...

Страница 12: ...ut power 90 to 265 Vac 50 60 Hz fused IEC input includes spare fuse Or 30 to 72 VDC input Inputs 1 to 2 for power redundancy IEC Main Input Power 2 Optional Special order Mains input power 90 to 265 V...

Страница 13: ...s shown in Section 3 5 The Optical Gain Block has an input optical signal range of 10 to 10dBm for which the output will be stable at its nominated optical power Although the pump lasers will operate...

Страница 14: ...3 Pressing ENT bottom to display parameters 4 If any fault listed above occurred there will be an alarm Red flashing Microprocessor will shut off the laser pump automatically and digital panel will sh...

Страница 15: ...eset these in case of a power failure The factory default setting of the unit is to have an IP address of 192 168 1 50 The factory default setting is to have the laser switched off for all models LCD...

Страница 16: ...net mask R GW Adjustable list display the gateway address S TR1 Adjustable list display the TRAP1 address T TR2 Adjustable list display the TRAP2 address U LCD Contrast Level Adjustable list display t...

Страница 17: ...ement ports RS232 port be suitable for examining AT 52 EDFA parameters and some system configuration by PC machine RS232 port SNMP Simple network management protocol Before connection AT 52 EDFA serie...

Страница 18: ...8 Nonuse Nonuse RJ 45 Pin assignment Straight Cross AT 52 EDFA Adapter AT 52 EDFA HUB AT 52 EDFA 1 IRD 1 OTD 1 IRD 1 IRD 2 IRD 2 OTD 2 IRD 2 IRD 3 OTD 3 IRD 3 OTD 3 OTD 6 OTD 6 IRD 6 OTD 6 OTD Straig...

Страница 19: ...r all network connections to avoid confusion or inconvenience when upgrading to Fast Ethernet devices in the future 4 Cascade length provision IEEE 802 3 standard prescribes that through twisted pair...

Страница 20: ...DB9 connector in AT 52 EDFA series and PC side According to the following steps to connect cables 1 Through RS232 DB9 cable connect a super terminal program PC to RS232 port in AT 52 EDFA series back...

Страница 21: ...e web browser to check the working condition and basic parameters of the amplifier it supports IE Chrome Firefox opera and other main web browser The following example are based on Opera browser 1 Fin...

Страница 22: ...AT5200 FTTX Multiport EDFA Solutions Provider for FTTx RFoG and HFC www ascentcomtec com Page 22 of 29...

Страница 23: ...AT5200 FTTX Multiport EDFA Solutions Provider for FTTx RFoG and HFC www ascentcomtec com Page 23 of 29 2 Open web browser input the IP add For example 192 168 0 22 Then login version...

Страница 24: ...AT5200 FTTX Multiport EDFA Solutions Provider for FTTx RFoG and HFC www ascentcomtec com Page 24 of 29 User Name admin Password 123456 3 The working condition version...

Страница 25: ...AT5200 FTTX Multiport EDFA Solutions Provider for FTTx RFoG and HFC www ascentcomtec com Page 25 of 29 4 Items guide on the left click to enter...

Страница 26: ...AT5200 FTTX Multiport EDFA Solutions Provider for FTTx RFoG and HFC www ascentcomtec com Page 26 of 29...

Страница 27: ...AT5200 FTTX Multiport EDFA Solutions Provider for FTTx RFoG and HFC www ascentcomtec com Page 27 of 29...

Страница 28: ...duce the amplifier s performance and can result in permanent damage to the device It is recommended that the fiber connectors be cleaned prior to connection or reconnection to the system No lights ON...

Страница 29: ...Unit 1907 600 Luban Road 2710 Thomes Ave 200023 Shanghai CHINA Cheyenne WY 82001 USA Phone 86 21 60232616 Phone 1 203 816 5188 EUROPE VIETNAM Pfarrer Bensheimer Strasse 7a 15 F TTC Building Duy Tan S...