ARF122B 1.2GHz MDU RF Amplifier 

 

 

Solutions Provider for FTTx, RFoG and HFC www. ascentcomtec.com 

Page 7 of 15 

 

 

 

 

Ensure adequate cooling and ventilation as specified. 

 

The installation and operation manual should be read and understood before units are put into use. 

 

Dangerous voltages are present within the unit at all times.  

Mains power kills.

 

 

Do not operate unit without all covers and panels properly installed.  

Mains power kills. 

Cleaning 

Use only a damp cloth for cleaning front panel. Use a soft dry cloth to clean top of unit.  Do not use spray cleaner of 
any kind. 

Overloading 

Overloading wall outlets and extension cords can result in a risk of fire or electric shock.  Use approved electrical 
cords. 

Damage requiring service 

Unplug unit and refer servicing to Ascent Communication Technology qualified service personnel only. 

Servicing 

Do not attempt to service this unit yourself.  Refer all servicing to Ascent Communication Technology qualified 
service personnel only. 

 

On receiving your new ARF122B, you should carefully unpack and examine the contents for loss or damage that 
may have occurred during shipping. Refer to warranty registration if loss or damage has occurred. The ARF122B 
should consist of the following: 
 

Qty  Description 

ARF122B unit 

Product user manual ( Optional ) 

Certificate of performance (includes test result sheet) 

 

 

 

Keep all packing boxes and packaging of the ARF122B for future transport. 
Use only the original packaging of the ARF122B when transporting. This packaging has been specifically designed to 
protect the equipment. 
 
 

Содержание ARF120B Series

Страница 1: ...ARF122B 1 2GHz MDU RF Amplifier Quick Reference Guide Revision A...

Страница 2: ...uction in any manner whatsoever without the express written permission of Ascent Communication Technology is strictly forbidden This document is produced to assist professional and properly trained pe...

Страница 3: ...ifications 5 2 InstallationandConfiguration 7 2 1 Precautions 7 2 2 Equipment Inventory 7 2 3 Packaging and Transportation 7 2 4 Opening the Unit 8 2 5 Unit Installation Points 8 2 6 Install and Check...

Страница 4: ...s suitable for MDU FTTB or FTTC applications with outputs up to 108 dB V The ARF120B 1 2 GHz MDU amplifier has field upgradeable diplexers and filters with JXP style plug in PADs and EQs along with pl...

Страница 5: ...equalization Second output can be selected via splitter or tap uency split Compact design Forward Path Specifications Item Value Pass Band 85 258 MHz to 1208 MHz Gain 42 dB FrequencyResponse 0 75 dB I...

Страница 6: ...dB 1 dB step OutputEqualizer 0 dB to 12 dB 1 dB step FrequencyResponse 0 75 dB Return Loss 18 dB RF Test Point 20 dB Noise Figure 5 6 dB Output Level 119 0 dB V BER 1 x 10 8 MER 35 dB General Specifi...

Страница 7: ...pproved electrical cords Damage requiring service Unplug unit and refer servicing to Ascent Communication Technology qualified service personnel only Servicing Do not attempt to service this unit your...

Страница 8: ...he case halves The unit must always be mounted with the heat dissipating fins vertical and nothing obstructing the flow of air through the fins A clearance of 50 mm must be left between the sides of t...

Страница 9: ...s into AC input power port above please make sure that the centre pin is between 30 mm and 35 mm when measured from the seating area of the connector to the tip of the centre pin see below If the pin...

Страница 10: ...onnector and in good condition see below Sealing O ring location and centre pin length Apply water tight adhesive lined heat shrink tubing as per manufacturer s instructions to cover the whole connect...

Страница 11: ...forward output level via RF input Test Point measure the signal level if it is not specified in the system design you must adjust the Input level higher or lower Set up the tilt If the high frequency...

Страница 12: ...ath Verify the Reverse input level and reverse output lever via RF Test Point measure the signal level if it is not specified in the system design you must adjust the Input level higher or lower If th...

Страница 13: ...ARF122B 1 2GHz MDU RF Amplifier Solutions Provider for FTTx RFoG and HFC www ascentcomtec com Page 13 of 15 1 Move cover 2 Must change the Diplex 2pcs HPF LPF and EQ 3 Mount Cover...

Страница 14: ...th factory recommendations The liability of Ascent Communication Technology under this warranty is solely limited to repairing replacing or issuing credit provided that The warranty does not cover the...

Страница 15: ...USA Unit 1907 600 Luban Road 2710 Thomes Ave Cheyenne 200023 Shanghai CHINA WY 82001 USA Phone 86 21 60232616 Phone 1 203 816 5188 EUROPE VIETNAM Pfarrer Bensheimer Strasse 7a 15 F TTC Building Duy Ta...

Отзывы: