![Ascent Communication Technology ARF120B Series Скачать руководство пользователя страница 12](http://html1.mh-extra.com/html/ascent-communication-technology/arf120b-series/arf120b-series_quick-reference-manual_2980874012.webp)
ARF122B 1.2GHz MDU RF Amplifier
Solutions Provider for FTTx, RFoG and HFC www. ascentcomtec.com
Page 12 of 15
2.
Balancing the Reverse Path
Verify the Reverse input level and reverse output lever via RF Test Point, measure the signal
level, if it is not specified in the system design, you must adjust the Input level higher or
lower.
If the high-frequency signal reduced in the course of transmitting, you may adjust the
variable equalizer EQ to get a suitable equalization.