COMPONENTS
AND
FUNCTION
BARISTA
T
PLUS/ZERO
COLD
WATER
DISTRIBUTOR
This part, placed in the right side, under the
boiler is a special fitting that distributes the cold
wáter to the steam boiler, the coffee groups,
the heat‐exchanger and the mixer of the hot
wáter dispenser.
In the connection of the heat‐exchanger there is
a non‐return valve.
INLET
WATER
TO
FILL
BOILER
This is the solenoid connected with the
boiler level probe. When the level is
low, the solenoid open and refill the
boiler.
In one side have connected a non‐
return valve.