Multi Variable Air Conditioners Floor and Ceiling Type Indoor Unit 

 

No. 

Name 

Graphics 

Quantity 

Purpose 

wire controller package (including wire 

controller, emergency bottom case, 

instruction manual, screws, packing box)   

 

 

1set 

Control indoor unit 

Remote controller   

 

0 or 1 

optional parts (including 

#7 batteries) 

Sponge for drainage pipe 

 

wrap water pipe and 

rubber cork for 

condenser 

Insulating materials   

   

 

used for the joint of gas 

pipe and liquid pipe for 

indoor unit   

Corrugated pipe   

 

0 or 1 

Diameter of air 

pipe≥15.9

 

Union nut 

 

1 or 2 

one for the model with 

corrugated pipe; two for 

other models 

Spring washer M8, nut M8, nut with 

washer M8, washer M8 

 

 

Used for hanging the 

indoor unit 

Tieline   

 

Wrap the sponge at the 

connection position   

others 

User Manual: 1 copy   

Loosen-leaf of Instruction Manual : 1 copy (harmful substance content table) 

Qualified Certificate: 1 copy 

Bar Code : 1 copy 

3.2 Location for Installation 

1)  The top holder must be strong enough to support unit's weight. 

2)  Drain pipe can drain water out easily. 

3)  There is no obstacle at inlet or outlet. Please ensure good air circulation. 

4)  In order to make sure the space for maintenance, please install the indoor unit according to the 

dimension described below. 

5)  Keep the unit away from heating source, inflammable gas or smoke. 

6)  This is a concealed ceiling type unit. 

7)  Indoor unit, outdoor unit, power cord and electric wire should stay at least 1m from the TV set and 

radio. Otherwise, these electrical appliances may have image interference and noise. (Even if the 

distance is 1m, when there is strong electric wave, noise may still occur.)     

8)  The appliance shall not be installed in the laundry. 

Unit: mm 

 

Fig 3.1 

Содержание AMV5-22SLD

Страница 1: ...onditioners Models AMV5 22SLD AMV5 25SLD AMV5 28SLD AMV5 32SLD AMV5 36SLD AMV5 40SLD AMV5 45SLD AMV5 50SLD AMV5 56SLD AMV5 63SLD AMV5 72SLD Thank you for choosing Air Conditioners please read this own...

Страница 2: ......

Страница 3: ...re only for your reference For sales or production reasons these graphics are subject to change by manufacturer without prior notice 8 Under the standby status the unit will consume a little power for...

Страница 4: ...9 4 3 Installation and Test of Drain Pipe 9 4 4 Installation of Air Duct 12 4 5 Installation of Wired Controller 15 5 Wire Connection 15 5 1 Connection of Wire and Wiring Board Terminal 15 5 2 Power...

Страница 5: ...ng into the socket so as to avoid electric shock Please do not connect the ground wire to gas pipe water pipe lightning rod or telephone line Be sure to use the exclusive accessory and part to prevent...

Страница 6: ...ay happen Do not expose the unit to the moist or corrosive circumstances Electrify the unit 8 hours before operation Please switch on for 8 hours before operation Do not cut off the power when 24 hour...

Страница 7: ...Cooling Heating Fan Dehumidifying Fan Speed Adjustment Temperature Adjustment X fan Function Quiet Function Sleep Function Save Function E heater Function Memory Function Absence Function Timer Functi...

Страница 8: ...position 9 others User Manual 1 copy Loosen leaf of Instruction Manual 1 copy harmful substance content table Qualified Certificate 1 copy Bar Code 1 copy 3 2 Location for Installation 1 The top hold...

Страница 9: ...ntroller L m feet Wire size mm 2 AWG Material Standard Remarks Light Ordinary polyvinyl chloride sheathed cord 60227 IEC 52 60227 IEC 53 L 250m L 820 1 5feet 2 0 75 2 1 25 2 AWG18 2 AWG16 IEC 60227 5...

Страница 10: ...4pc at 40 C ambient temperature when laying across plastic pipe Air switch is D type and used at 40 C If actual installation condition varies please lower the capacity appropriately according to the...

Страница 11: ...1000 200 450 474 AMV5 72SLD 1360 415 1300 200 450 474 4 1 2 Punching of Bolt Spots and Bolt Installation Punch holes on the installation area according to the 4 spots on the paper pattern The punching...

Страница 12: ...re connection wire of IDU and ODU that need to be connected with the indoor unit Punch holes on the ceiling air return opening or air inlet Ceiling may have to be strengthened to make it level and to...

Страница 13: ...be as short as possible and slope downward for at least 1 2 so that condensate can drain out easily 2 Size of the drainage hose must not be smaller than that of the drain pipe 3 Install the drain pip...

Страница 14: ...4 3 2 Fig 4 3 3 4 When connecting several drain pipes follow the instruction as indicated in Fig 4 3 4 Choose the drain collecting pipe that matches with unit capacity Fig 4 3 4 5 5 For indoor units t...

Страница 15: ...0mm Fig 4 3 9 11 Drain pipes should have a downward slope of at least 1 2 in order to prevent pipes from sagging install hanger bracket at intervals of 1000 1500mm Fig 4 3 10 4 3 3 Test of Drainage Sy...

Страница 16: ...off power supply disconnect power cord and then put on the electric box cover 2 Check if the water drains smoothly from the drain pipe and check if there is water leakage on the connection pipe 3 Arr...

Страница 17: ...1 Return Air Duct 6 Transition Pipe 2 Canvas Duct 7 Supply Air Duct 3 Return Air Blinds 8 Diffuser 4 Hanger Rod 9 Diffuser Connector 5 Supply Air Outlet 4 4 2 Shape and Size of Air Outlet and Air retu...

Страница 18: ...wire 4 Air return from the bottom will produce more noise than air return from the back So we suggest you to add a noise damper and static pressure case to lower noise if you choose air return from t...

Страница 19: ...d correct operation 6 Install specialized branch circuit breaker according to related laws and regulations and electrical standards 7 All wiring must use pressure terminal or single wire Multi twisted...

Страница 20: ...Use a screwdriver to remove screw on the wiring board of air conditioner 3 Use a round terminal fastener or a plier to securely fasten the round terminal with each core wire of the multi core wire 4 C...

Страница 21: ...munication line with the wire clamp on the electric box 5 In order to ensure the reliability of communication between IDU and ODU and the communication among each IDU add a matched resistance supplied...

Страница 22: ...Communication between IDU and wired controller is H1 H2 3 One indoor unit can connect two wired controllers master wired controller and sub master wired controller 4 One wired controller is able to co...

Страница 23: ...Multi Variable Air Conditioners Floor and Ceiling Type Indoor Unit 19 Fig 5 5...

Страница 24: ...its are blocked 2 Check whether grounding wire is in good condition 3 Check whether wire connection is correct 4 Connect the power and check whether the display screen of wired controller shows any ch...

Страница 25: ...or windows is open Inlet and outlet of IDU are blocked Setting temperature is too high Refrigerant is insufficient e g refrigerant leakage Poor heating effect The filter is dirty Door or window is op...

Страница 26: ......

Страница 27: ......

Страница 28: ......

Отзывы: