Multi Variable Air Conditioners Floor and Ceiling Type Indoor Unit 

 

1 Safety Precautions   

 

Means  items  that  must  be  forbidden!  Otherwise,  it  may  lead  to  personal  injury  or  death  or  serious 

damage. 

  Means items that must be followed! Otherwise, it may lead to personal injury or property loss. 

 

Follow this instruction to 
complete the installation 
work. Please carefully read 
this manual before unit 
startup and service. 

 

 

Installation should be 
conducted by dealer or 
qualified personnel. Please 
do not attempt to install the 
unit by yourself. Improper 
handling may result in water 
leakage, electric shock or fire 
disaster etc. 

 

Before installation, please 
check if the power supply is 
in accordance with the 
requirements specified on 
the nameplate. And also take 
care of the power safety. 

 

 

Make sure the unit can be 
earthed properly and soundly 
after plugging into the socket 
so as to avoid electric shock. 
Please do not connect the 
ground wire to gas pipe, water 
pipe, lightning rod or 
telephone line.   

 

Be sure to use the exclusive 
accessory and part to 
prevent the water leakage, 
electric shock and fire 
accidents. 

 

Frefrigerant leakage happens 
during installation, please 
ventilate immediately. 
Poisonous gas will emerge if 
the refrigerant gas meets fire. 

 

Wire size of power cord 
should be large enough.The 
damaged power cord and 
connection wire should be 
replaced by exclusive cable. 

 

After connecting the power 
cord, please fix the electric 
box cover properly in order to 
avoid accident. 

 

Never fail to comply with the 
nitrigen charge 
requirements.Charge 
nitrogen when welding pipes. 

 

Never short-circiut or cancel 
the pressure switch to prevent 
unit damage.   

 

Please firstly connect the 
wired controller before 
energization, otherwise 
wired controller can not be 
used. 

 

 

Before using the unit, please 
check if the piping and wiring 
are correct to avoid water 
leakage, refrigerant leakage, 
electric shock, or fire etc. 

 

Содержание AMV5-22SLD

Страница 1: ...onditioners Models AMV5 22SLD AMV5 25SLD AMV5 28SLD AMV5 32SLD AMV5 36SLD AMV5 40SLD AMV5 45SLD AMV5 50SLD AMV5 56SLD AMV5 63SLD AMV5 72SLD Thank you for choosing Air Conditioners please read this own...

Страница 2: ......

Страница 3: ...re only for your reference For sales or production reasons these graphics are subject to change by manufacturer without prior notice 8 Under the standby status the unit will consume a little power for...

Страница 4: ...9 4 3 Installation and Test of Drain Pipe 9 4 4 Installation of Air Duct 12 4 5 Installation of Wired Controller 15 5 Wire Connection 15 5 1 Connection of Wire and Wiring Board Terminal 15 5 2 Power...

Страница 5: ...ng into the socket so as to avoid electric shock Please do not connect the ground wire to gas pipe water pipe lightning rod or telephone line Be sure to use the exclusive accessory and part to prevent...

Страница 6: ...ay happen Do not expose the unit to the moist or corrosive circumstances Electrify the unit 8 hours before operation Please switch on for 8 hours before operation Do not cut off the power when 24 hour...

Страница 7: ...Cooling Heating Fan Dehumidifying Fan Speed Adjustment Temperature Adjustment X fan Function Quiet Function Sleep Function Save Function E heater Function Memory Function Absence Function Timer Functi...

Страница 8: ...position 9 others User Manual 1 copy Loosen leaf of Instruction Manual 1 copy harmful substance content table Qualified Certificate 1 copy Bar Code 1 copy 3 2 Location for Installation 1 The top hold...

Страница 9: ...ntroller L m feet Wire size mm 2 AWG Material Standard Remarks Light Ordinary polyvinyl chloride sheathed cord 60227 IEC 52 60227 IEC 53 L 250m L 820 1 5feet 2 0 75 2 1 25 2 AWG18 2 AWG16 IEC 60227 5...

Страница 10: ...4pc at 40 C ambient temperature when laying across plastic pipe Air switch is D type and used at 40 C If actual installation condition varies please lower the capacity appropriately according to the...

Страница 11: ...1000 200 450 474 AMV5 72SLD 1360 415 1300 200 450 474 4 1 2 Punching of Bolt Spots and Bolt Installation Punch holes on the installation area according to the 4 spots on the paper pattern The punching...

Страница 12: ...re connection wire of IDU and ODU that need to be connected with the indoor unit Punch holes on the ceiling air return opening or air inlet Ceiling may have to be strengthened to make it level and to...

Страница 13: ...be as short as possible and slope downward for at least 1 2 so that condensate can drain out easily 2 Size of the drainage hose must not be smaller than that of the drain pipe 3 Install the drain pip...

Страница 14: ...4 3 2 Fig 4 3 3 4 When connecting several drain pipes follow the instruction as indicated in Fig 4 3 4 Choose the drain collecting pipe that matches with unit capacity Fig 4 3 4 5 5 For indoor units t...

Страница 15: ...0mm Fig 4 3 9 11 Drain pipes should have a downward slope of at least 1 2 in order to prevent pipes from sagging install hanger bracket at intervals of 1000 1500mm Fig 4 3 10 4 3 3 Test of Drainage Sy...

Страница 16: ...off power supply disconnect power cord and then put on the electric box cover 2 Check if the water drains smoothly from the drain pipe and check if there is water leakage on the connection pipe 3 Arr...

Страница 17: ...1 Return Air Duct 6 Transition Pipe 2 Canvas Duct 7 Supply Air Duct 3 Return Air Blinds 8 Diffuser 4 Hanger Rod 9 Diffuser Connector 5 Supply Air Outlet 4 4 2 Shape and Size of Air Outlet and Air retu...

Страница 18: ...wire 4 Air return from the bottom will produce more noise than air return from the back So we suggest you to add a noise damper and static pressure case to lower noise if you choose air return from t...

Страница 19: ...d correct operation 6 Install specialized branch circuit breaker according to related laws and regulations and electrical standards 7 All wiring must use pressure terminal or single wire Multi twisted...

Страница 20: ...Use a screwdriver to remove screw on the wiring board of air conditioner 3 Use a round terminal fastener or a plier to securely fasten the round terminal with each core wire of the multi core wire 4 C...

Страница 21: ...munication line with the wire clamp on the electric box 5 In order to ensure the reliability of communication between IDU and ODU and the communication among each IDU add a matched resistance supplied...

Страница 22: ...Communication between IDU and wired controller is H1 H2 3 One indoor unit can connect two wired controllers master wired controller and sub master wired controller 4 One wired controller is able to co...

Страница 23: ...Multi Variable Air Conditioners Floor and Ceiling Type Indoor Unit 19 Fig 5 5...

Страница 24: ...its are blocked 2 Check whether grounding wire is in good condition 3 Check whether wire connection is correct 4 Connect the power and check whether the display screen of wired controller shows any ch...

Страница 25: ...or windows is open Inlet and outlet of IDU are blocked Setting temperature is too high Refrigerant is insufficient e g refrigerant leakage Poor heating effect The filter is dirty Door or window is op...

Страница 26: ......

Страница 27: ......

Страница 28: ......