Installation, Operation and Maintenance Manual
【
H-A070-E-3
】
3-Way Ball Valve Type23 Pneumatic Actuated Type AR 15-50mm (1/2”-2”)
6
6. Specifications of actuator
Actuation
Nominal size
Angle adjustment
range
Standard operating
pressure
Ambient
temperature range
Double acting
Air to open
Air to shut
15-50mm
(½”-2”)
Cannot adjust
an angle
0.4-0.7 MPa
{4.1-7.1 kgf/ cm
2
}
[70-105 psi]
-10 to 60°C
[14 to 150°F]
7. Specifications of filter regulator
Actuation
Nominal size
Type sign
Air supply bore
Element rated
filtration
Double acting
Air to open
Air to shut
15-50mm
(½”-2”)
ARU2-02-8A-B Rc1/4
5
μ
m
Actuation
Nominal size Actuator type
Air consumption
NL per 1 open & shut
at 0.4MPa
Air supply bore
Double acting
15-25mm
(½”-1”)
AR040DA20
0.6 Rc1/8
32-50mm
(1¼”)-2”)
AR050DA30
1.3 Rc1/4
Air to open
Air to shut
15-20mm
(½”-¾”)
AR040NC20
0.2 Rc1/8
25mm
(1”)
AR050NC30
0.4
Rc1/4
32-50mm
(1¼”)-2”)
AR063NC40
0.8
JIS sign