14

 

  How to connect a tube to a fitting

 

 

Flowell 20 series

 

1)

  Cut a tube at right angle. Pass the nut through the tube. 

2)

  Using the dedicated tool, force the ring to fit into the inner surface of the tube. 

3)

  Insert  the  tube  provided  with  the  ring  into  the  main  body  by  hand.  Form  the  tube  end  straight 

beforehand. 

4)

  Place the nut and turn it by hand until it will not go any further. Then use a spanner to tighten the nut by   

giving a 1/2 turn. 

 

Flowell 60 series

 

1)

  Cut a tube at right angle. Pass the nut through the tube. 

2)

  Using the dedicated tool, flare the tube.   

3)

  Insert the tube into the fitting. Turn nut up to the required clearance by spanner, after tightening by   

hand firmly. 

4)

  To check the tightness of union nut, use the dedicated gap gauges. 

 

Super Type Pillar Fitting

 

1)

  Cut a tube at right angle. Pass the union nut through the tube. 

2)

  Using the dedicated tool, force the sleeve to fit into the inner surface of the tube. 

3)

  Insert the tube provided with the ring into the main body by hand. Turn nut up to the required 

  clearance by spanner, after tightening by hand firmly. 

4)

  To check the tightness of union nut, use the dedicated gap gauges. 

 

Super 300 Type Pillar Fitting

 

1)

  Cut a tube at right angle. Pass the union nut through the tube. 

2)

  Using the dedicated tool, force the sleeve to fit into the inner surface of the tube. 

3)

  Assemble the sleeve to the fitting and then tighten the fitting until the union nut makes contact with 

the projection on the gauge ring and a click can be heard. 

 

Flare Type

 

1)

  Cut a tube at right angle. Pass the nut through the tube. 

2)

  Using the dedicated tool, flare the tube. 

3)

  Insert the tube into the fitting. Turn nut up to the required clearance by spanner, after tightening 

    by hand firmly. 

4)

  To check the tightness of union nut, use the dedicated gap gauges 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

For further information, see the instruction manuals issued by relevant fitting manufactures. 

 

Do not overtighten the nuts. (That may damage the fittings and nuts.) 

 

Make sure the flow direction of the valve is correct. 

 

Caution

 

Содержание Dymatrix AVCFV

Страница 1: ...t Materials 3 6 Specifications 4 7 How to select types 5 8 Dimension 6 9 How to operate 7 10 Technical data 8 12 Method of installation 9 13 Method of piping 10 16 Check items 11 17 Causes of defects...

Страница 2: ...User s Manual AVCFV 1 General cautions 1 2 AV V 029 EJ N2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 1 2...

Страница 3: ...User s Manual AVCFV 2 1 1 AV V 029 EJ N2 2 3 4 5 6 1 2 3 4...

Страница 4: ...Please contact us when use for the fluid containing the crystalline substance It would make the valve unable to seal 5 Use the products within the range of working pressure shown in this user s manua...

Страница 5: ...ing condition If cavitations are observed review the fluid pressure and piping design 3 Do not use the valve in negative pressure It can be damaged 4 Handle the products carefully to protect the clean...

Страница 6: ...User s Manual AVCFV 5 Parts Materials Parts Wetted parts Body Diaphragm Actuator O O ring Metal parts PTFE SUS304 Chemical resistant PTFE PVDF FKM EPDM F Kalrez 6190...

Страница 7: ...sure MPa Pilot port Tighten the torque N m Pilot 0 4 0 6 0 5 Max 0 3 Open control 0 15 0 3 Feed back control Rc1 8 FNPT1 8 6 4 6 35 4 35 10 90 0 6 87psi 5 5 times 10 60 Any direction Flowell 20 series...

Страница 8: ...E V FNPT1 8 n a N 06 6 x 4 Connection tubing size T 50 125 250 500 LF AVCFV 1000 2000 Super 300 Type Pillar Fitting Flare Type Tube mL min mL min O O rng 3 F 4 Viflon F 6190 Karlez 6190 Low Flow 06 1...

Страница 9: ...Pillar fitting P series Flowell 20 series Flowell 60 series Flare Type Super Type Pillar fitting Super 300 Type Pillar fitting P series For other fittings snsult us Tube diameter mm inch 6 4 6 35 4 3...

Страница 10: ...ithout the exhaust function The valve may not operate precisely Please leave the pilot air pressure off in case the valve is not used for long time The range of the flow rate differs with high viscosi...

Страница 11: ...xperimental values and the reference values AVCFVLF005 Differential pressure Flow rate Pilot pressure Flow rate 0 10 20 30 40 50 60 0 0 1 0 2 0 3 0 4 0 5 0 6 Differential Pressure MPa psi Pa 0 3MPa Pa...

Страница 12: ...sure MPa 43 5 36 25 29 21 75 14 5 7 25 Flow rate Pilot pressure 0 100 200 300 400 500 600 32 33 34 35 36 37 38 time sec Flow mL min 0 0 05 0 1 0 15 0 2 0 25 0 3 Pilot Pressure MPa 43 5 36 25 29 21 75...

Страница 13: ...V 12 Method of installation Flow direction Always flow medium in a specified direction The flow direction is marked on the product Always flow medium in a specified direction If omitted that may damag...

Страница 14: ...User s Manual AVCFV 13 Method of piping Flowell 20 series 1 2 Flowell 60 series Super Type Pillar fitting Super 300 Type Pillar fitting Flare Type...

Страница 15: ...e inner surface of the tube Insert the tube provided with the ring into the main body by hand Turn nut up to the required clearance by spanner after tightening by hand firmly To check the tightness of...

Страница 16: ...er or the like may break the product Metallic couplings may break the pilot ports of the product Always use sealing tape If you use other sealing materials leakage may occur If you use liquid sealing...

Страница 17: ...ds you to check them at least once a year When finding any problem or trouble call us Check points Check items Actuator Appearance flaw crack distortion discoloration Leakage of the pilot air Valve Ap...

Страница 18: ...Leakage in fully closed position The diaphragm is abraded Replace the valve Flaw in the diaphragm or body Foreign matter is caught in the valve Outer leakage from the valve The cap nuts are loose Ret...

Страница 19: ...pose of product improvement 2020 12 v07 110 0005 3 24 6 21 TEL 03 5826 8832 FAX 03 3834 7592 For inquiries contact Head Office Overseas Department Tel 81 3 5826 8831 Fax 81 3 3834 7592 21st Floor Ueno...

Отзывы: