background image

NOTE:

ESD sensitive product.
Use ESD protection equipment.

Particle filter

NOTE:

Handle sensor by holding PCB only. 

Never touch sensor with bare hands! Use clean gloves 

to avoid dust, grease or other contaminations. 
OBA shall not be subjected to any force.

NOTE:

To ensure airflow, and quick sensor response time to changes 

in environment: do not block particle filter!

Handling Manual

Senseair LP8

Miniature CO

2

 sensor module

for battery-powered applications

Installation and soldering

See IPC-J-STD-001 for acceptable soldering conditions in general.

Selective soldering machine (drag soldering method): soldering temperature 295°C during 3 seconds.

Hand soldering: soldering iron temperature 380°C during 2 seconds/pin.

Mechanical properties

Please refer to mechanical drawing of detailed specification regarding dimensions and tolerances.

Layout considerations:

Use cut-outs or slits in main board to reduce mechanical stress to sensor due to board thermal expansion.
To ensure stability, do install pin headers on boath sides of sensor.

 

part of AsahiKASEI

Document  Rev  

Page

ANO1332 

 

1 (2)