ASAHI KASEI
[AK4589]
MS0339-E-00
2004/09
-
40
-
Addr
Register
Name
D7 D6 D5 D4 D3 D2 D1 D0
01H Control
2
CKS1
DFS1
LOOP1
LOOP0
SDOS
DFS0 ACKS CKS0
Default
0 0 0 0 0 0 0 0
ACKS: Master Clock Frequency Auto Setting Mode Enable
0: Disable, Manual Setting Mode
1: Enable, Auto Setting Mode
Master clock frequency is detected automatically at ACKS bit “1”. In this case, the setting of DFS1-0
bits are ignored. When this bit is “0”, DFS1-0 bits set the sampling speed mode.
DFS1-0: Sampling speed mode (see Table 1)
The setting of DFS1-0 bits are ignored at ACKS bit “1”.
CKS0-1: Master clock frequency select (see Table 2)
SDOS:
SDTO1
source
select
0: ADC
1:
DAUX
SDOS bit should be set to “0” at TDM bit “1”.
In the case of PWADN bit =”0” and PWDAN bit =”0”, the setting of SDOS bit becomes invalid. And
ADC is selected.
The output of SDTO1 becomes “L” at PWADN bit =”0”.
LOOP1-0:
Loopback
mode
enable
00:
Normal
(No
loop
back)
01: LIN
→
LOUT1, LOUT2, LOUT3, LOUT4
RIN
→
ROUT1, ROUT2, ROUT3, ROUT4
The digital ADC output (DAUX1 input if SDOS = “1”) is connected to the digital DAC input. In
this mode, the input DAC data to SDTI1-3 is ignored. The audio format of SDTO1 at loopback
mode becomes mode 2 at mode 0, and mode 3 at mode 1, respectively.
10:
SDTI1(L)
→
SDTI2(L), SDTI3(L), SDTI4(L)
SDTI1(R)
→
SDTI2(R), SDTI3(R), SDTI4(R)
In this mode the input DAC data to SDTI2-4 is ignored.
11: N/A
LOOP1-0 bits should be set to “00” at TDM bit “1”.
In the case of PWADN bit =”0” and PWDAN bit =”0”, the setting of LOOP1-0 bits become
invalid. And ADC is selected. And it becomes the normal operation (No loop back).