User Manual - M0022
"TIME Pw ON"
– Time interval, sec., where the solenoid pull in winding will be active
"TIME Pw AND Pp ON"
- Time interval, sec., where the solenoid pull in and holding windings will
be active
"TIME Pp ON"
- Time interval, sec., where the solenoid holding winding will be active
"PERFORM CALIBRATION"
– entrance to the power supply calibration menu
"BRIGHTNESS"
– Adjusting of the screen backlight level
"ENABLE 24V SOLENOID"
– Used for testing 24V solenoids in the case when the maximum
voltage
of the tester is not enough for the operation of the solenoid. If this parameter is switched
on, during the test, at the first moment of time, the solenoid pull in and holding windings are
powered at the same time. The value "1" - on, "0"
– off
"MINIMUM TEST VOLTAGE"
,
"MAXIMUM TEST VOLTAGE"
- Displays the minimum and
maximum
voltage values that can be set during testing
WARNING!
The "PERFORM CALIBRATION" menu item is for entering the calibration
menu of
the power supply unit. Each M0022 is calibrated at the factory and recalibration is
required only in case of repairing, or after long time using. While updating the tester
firmware, recalibration is necessary, before you start it, you must disconnect the tester
wiring from the solenoid, and connect the power clamps for the measuring plates of the
black and red clamps to be connected (those from which the thin wire is connected). If the
power supply is calibrated incorrectly, the device will not work correctly.