CentreMIXX Owner’s Manual V1 © 2002 ARX Systems®
CentreMIXX Owner’s Manual V1 © 2002 ARX Systems®
4
Front Panel
Front Panel
Front Panel
Front Panel
Front Panel
Rear Panel
Rear Panel
Rear Panel
Rear Panel
Rear Panel
• Aux Input Mute switch and status LED
• Aux Input Level control
• Centre channel Master Level control
• Centre channel Master Mute switch and status LED
• AC Power status LED
• IEC 3 pin AC connector and integral fuseholder. Replace fuse with correct value
only: 100 - 120 V AC 1 amp, 220-240 V AC 0.5 amp. Please also refer to voltage
details on Page 2
• Left, Centre and Right channels Balanced XLR Outputs wired Pin 1 Ground, Pin
2+ (Hot), Pin 3 – (Cold)
• Left and Right Master XLR Inputs wired Pin 1 Ground, Pin 2+ (Hot), Pin 3 –
(Cold)
• Left and Right Aux XLR Inputs wired Pin 1 Ground, Pin 2+ (Hot), Pin 3 – (Cold)
• Aux Inputs Phase Reverse switch and status LED
5
Architects’ and Engineers’ Specifications
The unit shall be mounted in a standard 1 RU all steel chassis with extruded
aluminium front panel.
Each channel shall have a balanced female XLR input connector and a balanced
male XLR output connector mounted on the rear panel.
The Auxiliary input channels shall have a Level trim control on the front panel,
variable from infinity through to +10 dB. The Centre Channel Mix control shall also
be variable from infinity through to +10 dB. The Left and Right Channel shall have
unity Gain through the unit.
The Output Noise shall be –96dB unweighted. Input impedance shall be 44 KOhms
(22 KOhms unbalanced), and the output impedance shall be 200 Ohms (100 Ohms
unbalanced).
Maximum Output Level shall be +24dB
AC power range shall be switchable 100 to 120V or 220 to 240V AC, and shall be
connected to the unit via a standard three pin IEC connector, with built-in fuse and
voltage change switch.
The unit shall be the ARX CentreMIXX