Specifications
Input Impedance
Mic: 4 KOhms balanced, Line: 100 KOhms unbalanced
Input Gain
Mic: Variable 20 dB to 60 dBwith rear trim control
Line: –10 to +10 dB
Output Level (Max)
+ 21dB
Signal to Noise ratio
-90 dB ‘A’ weighted
Note: All inputs @ unity, Master @ unity
Distortion
@ Unity Gain
Below .005% 100Hz to 10 KHZ
Dynamic Range
115 dB
Mic Channel EQ
Low
100Hz 15dBCut/Boost
Mid
800Hz 15dB Cut/Boost, Broad Q
High
10KHz 15dBCut/Boost
Zone EQ
Low
100Hz 10dBCut/Boost
High
10KHz 10dBCut/Boost
Level Control
oo to +6dB Gain (0 to 11)
Hi Z Input Connectors
Phono (RCA type)
Balanced Output Connectors
Male XLR: Pin 1 Ground, Pin 2 +, Pin 3 –
Frequency Response
20Hz—20KHz ±1dB
Power Requirements
100-120/220-240 V AC, 50/60 Hz 8VA (8 watts)
on 3 pin IEC connector
Weight
5 lbs/2.2 Kg
Dimensions
19"W x 1¾"H x 6"D, 482 x 44 x 155mm
Options
BM-1 VCA Remote Level Control.
Optional DC
controlled VCA pack. Wall plate connects to
BarMIX via balanced cable with TRS jack
connector. Use 1 per Zone
Our policy is one of continuous improvement, and therefore designs may change
without notice. However, unless otherwise stated, specifications will always equal or
exceed those previously given. ARX® is a Registered Trade Mark of ARX Systems Pty
Ltd. BarMIX™ is a trade mark or ARX Systems Pty Ltd. Any other names and
trademarks are used for information purposes only, and no other intent is expressed
or implied
This symbol indicates that a Slow Blow
fuse is used in this equipment. Replace
with same type and value only
This symbol is intended to alert you to
the presence of uninsulated dangerous
voltage within the product's enclosure
that may be of sufficient magnitude to
constitute a risk of electric shock.
This symbol is intended to alert you to
the presence of important operating
instructions contained in this owner's
manual
WARNING SYMBOLS USED
ON THIS EQUIPMENT
IMPORTANT
- PLEASE READ THIS FIRST
THIS IS A DUAL VOLTAGE UNIT. IT IS ESSENTIAL THAT YOU CHECK THAT THE VOLTAGE ON
THE FUSEHOLDER COVER BELOW THE AC CONNECTOR ON THE REAR OF THE CHASSIS IS
SET CORRECTLY BEFORE CONNECTING IT TO AC POWER.
To change, pull fuseholder out and rotate 180
o
, then push in again. Do not insert power
cable into unit until voltage has been correctly set. Do not connect power cable to AC
power until voltage has been correctly set
THIS IS SET FOR 100 V
AC TO 120 V AC
OPERATION
THIS IS SET FOR 220 V
AC TO 240 V AC
OPERATION
Complies with 89/336/EEC EMC Di-
rective, amended by 92/31/EEC and
93/68/EEC; meets the following
standards:EN 55013 : 1990, Sections
3.2 and 3.5, EN 55020 : 1988, Sections
4.3, 5.4, 6.2, 7.0, 8.0., and EN 60950 :
1994 Low Voltage Directive
Complies with Australian Standard AS/
N25 1053
Our policy is one of continuous im-
provement, and therefore designs may
change without notice. However, un-
less otherwise stated, specifications
will always equal or exceed those pre-
viously given.