ARX AV stream Скачать руководство пользователя страница 3

AVstream Owner’s Manual V1.2 © 2007 CE ARX Systems®

AVstream Owner’s Manual V1.2 © 2007 CE ARX Systems®

4

Front Panel

Rear Panel

ARCHITECTS’ AND  ENGINEERS’ SPECIFICATIONS
The signal processor shall be mounted in a steel chassis six inches deep and one rack unit high.

The unit shall be a Zoner/Mixer, i.e, it shall accept inputs from four separate stereo sources and

composite video sources as well as a microphone, and send them to two separate zones.  A

switch on the rear panel shall switch the output of the two zones to either stereo (Left and

Right), or Mono.

The microphone input shall have a level control and two way Equalisation controls. The micro-

phone connector shall be a balanced XLR input with an Input impedance of 4 K Ohms. There

shall also be  an input for a ducker control to attenuate line inputs by 20 dB, and LEDs to indicate

microphone status. The microphone shall be able to be routed to either or both output zones.
Each Line source shall have High Z Left and Right phono (RCA type) connectors, with associat-

ed Gain trim controls –10dB to +10 dB on the rear panel, and an overall line level control on

the front panel. A switch and status LED on the front panel shall indicate which source is active

•  Microphone Zone assign switches and LEDs
•  Microphone Level control
•  EQ controls for the microphone
•  Zone A program source switches, with label panels and LED

indicators to show active source

•  Zone A Line level control
•  Zone A Loudness switch and status LED
•  Zone A Master Level control
•  Zone A and B Output Level LED metering
(

Zone B functions identical to Zone A)

•  IEC 3 pin AC connector and integral fuseholder. Replace fuse with correct

value only: 100 - 120 V AC 1 amp, 220-240 V AC 0.5 amp. Please also
refer to voltage details on Page 2

•  Zone A and B Balanced XLR Outputs wired Pin 1 Ground, Pin 2+ (Hot), Pin

3 – (Cold)

•  Zone A and B Composite video Outputs wired Sleeve Ground, Cetre Pin+

(Hot)

•  All Outputs to Mono switch
•  Sources 1, 2, 3 and 4 Input Gain trim controls

•  Sources 1, 2, 3 and 4 Phono (RCA type) ASudio and Video input connectors
•  Balanced XLR microphone connector
•  Microphone Gain trim control

5

•  TRS jack connector for Mic

override (Press-to-talk ducker)
to attenuate line inputs by 20
dB. Wired so that shorting Tip
and Ring enables ducker

in each zone. These switches shall be interlocking so that only one of the four input sources per

zone can be selected at one time.
Each Zone shall have an Equalisation control and the option of Local or Remote Master output

level control. Each Master output shall have a dedicated 5 LED metering display
Input source impedance shall be 100K Ohms, and the input headroom shall be +21dB. The

frequency response (all channels and masters) shall be 20 Hz to 20 KHz, ±1dB. The Output

impedance shall be 300 ohms balanced, and the maximum Output level shall be +21dB, with a

Signal to Noise ratio at unity of -90 dB ‘A’ weighted. Audio Output connectors shall be Balanced

XLR type; Video Output connectors shall be RCA type. THD shall be below .005%, 100Hz to 10

KHZ, and the unit shall have a dynamic range of 111dB.

Power shall be supplied via a removable mains cable, connecting to an IEC connector with an

integral fuse and voltage change switch on the unit’s rear panel.
The Zoner/Mixer shall be the ARX AV Stream.

Отзывы: