Command Line Interface
Special Commands
MPORT
28
www.arwestcom.com
3.3.2. MPORT
The MPORT is an object that responsible for maintenance serial port interface configurations
such as data rate and number of bits in a byte.
MPORT [Parameter Name] [Parameters List] [/?]
Note:
ArWest radio modem’s does not support data flow and parity on the maintenance serial port.
MPORT operates using 8 bits in one byte fixed (not configurable).
The radio modem with none-dedicated maintenance serial port must keep CTS line always active
in MPORT mode (DP/MP is low).
3.4. Special Commands
3.4.1. ALARM
The ALARM command is intended to set up the alarm indication mode and alarm control lines’
behavior.
ALARM [Parameter Name] [Parameters List] [/?]
Parameter Name
Parameter List
RATE
0 – Auto.
1 – 1200 baud
2 – 2400 baud
3 – 4800 baud
4 – 9600 baud
5 – 14400 baud
6 – 19200 baud
7 – 38400 baud
8 – 57600 baud
9 – 115200 baud, a default setting
Parameter Name
Parameter List
TTL1
0 – TTL_OUT1 = logic “1”
1 – TTL_OUT1 = TTL_IN, received from remote unit (default settings)
TTL2
0 – TTL_OUT2 = logic “1”
1 – TTL_OUT2 = TTL_IN2, received from remote unit (default settings)
2 – TTL_OUT2 = SYNC Loss
3 – TTL_OUT2 = BER > BERTH or SYNC Loss
BERTH
1– BER Threshold >10
–3
(default threshold level for BER)
2 – BER Threshold BER >10
–2