Command Line Interface
Networking Commands
LINK
26
www.arwestcom.com
Note:
LINK FHOP and LINK CHAN commands can be processed only if Frequency Map is defined.
Auto-scanning may not start automatically, only when scanning requested via CLI command (see
LINK CHAN 0 and STATE commands).
The frequency defined by CHAN parameter is not valid if Frequency Hoping mode is selected.
MOD
1 – DBPSK
2 – DQPSK, a default settings
3 – D8PSK
4 – D16QAM
5 – GMSK
6 – 4FSK
PWRB / PWRW
0 – Automatic Transmit Power control, a default setting for Remote units
(15 – 30) / (30 – 1000) – RF output Power in dBm / mW
PROT
1 – “Simplex Receiver” a default setting (see note below)
2 – “Simplex Transmitter”
3 – “Half Duplex” Base (reserved)
4 – “Half Duplex” Repeater (reserved)
5 – Not used
6 – Not used
7 – “TRMB Receiver” (used with GMSK modulation)
8 – “TRMB Transmitter” (used with GMSK modulation)
9 – “Transparent w/EOT” Repeater (used with GMSK and 4FSK)
10 – “Repeater” (ArWest Proprietary Simplex)
11 – “TRMB Repeater” (used with GMSK modulation)
12 – “Transparent w/EOT” Receiver (used with GMSK and 4FSK)
13 – “Transparent w/EOT” Transmitter (used with GMSK and 4FSK)
14 – “STL Receiver” (used with 4FSK modulation)
15 – “STL Transmitter” (used with 4FSK modulation)
16 - Not used
17 - “Fast Async” Receiver (used with GMSK and 4FSK)
18 - “Fast Async” Transmitter (used with GMSK and 4FSK)
19 - “Transparent w/EOT Character” Receiver (used with GMSK and 4FSK)
20 - “Transparent w/EOT Character” Transmitter (used with GMSK and 4FSK)
PWRB / PWRW
(15 – 30) / (30 – 1000) – RF output Power in dBm / mW
RTR
0 – No Retransmission in the wireless cluster
1 – There is Repeater in the wireless cluster, valid for Base only
SCRAM
0 – No Scrambling (a default setting)
(1 – 255) – Seed for Pseudo-Random Sequence Generator
FEC
0 – Disable Forward Error Correction (FEC), a default setting
1 – Enable Reed-Solomon encoding
CHAR
(0 – 255) – defines the ASCI code of the symbol indicating the end of a data
chunk of “Transparent w/EOT Character” protocol.
ADDR
Indicates the number of address bytes of “STL” protocol’s data frame.
CLKCORR
0 – Disables Clock Correction algorithm of STL protocol
1- Enables Clock Correction algorithm of STL protocol.
Parameter Name