Electrical and Environmental Specifications

Electrical

Ethernet:

4 x 10/100/1000 Base-T auto-sensing Ethernet RJ45 interface

Power over Ethernet IEEE 802.3at and 802.3af 48VDC (nominal)

Power:

Direct DC source: 48Vdc nominal, +/- 5%

Power over Ethernet (PoE): 802.3at and 802.3af complaint source

Environmental

Operating:

Temperature: 0

°

C to +40

°

C (+32

°

F to +104

°

F)

Humidity: 5% to 93% non-condensing

Storage and transport:

Temperature: -40

°

C to +70

°

C (-40

°

F to +158

°

F)

Humidity: 5% to 93% non-condensing

Regulatory Information

AP11D RMN: APINH303.

Safety and Regulatory Compliance

If a power adapter other than the Aruba-approved adapter is used in the US or Canada, it should be NRTL listed, 

without an output rated 48VDC, minimum 1.2A, marked “LPS” and “Class 2”, and suitable for plugging into a 

standard power receptacle in the US and Canada.

!

RF Radiation Exposure Statement:

 This equipment complies with RF radiation exposure limits. This equipment 

should be installed and operated with a minimum distance of 13.78 inches (35cm) between the radiator and 

your body for 2.4 GHz and 5 GHz operations. This transmitter must not be co-located or operating in conjunction 

with any other antenna or transmitter. 

!

Déclaration sur les limites d'exposition aux radiofréquences :

 

cet équipement est conforme aux limites 

d'exposition aux rayonnements radioélectriques spécifiées. Il doit être installé et utilisé à une distance minimale 

de 35 cm par rapport à votre corps pour les fréquences de 2,4 et 5 GHz. Cet émetteur-récepteur ne doit pas être 

utilisé ou situé à proximité d'autres antennes ou émetteurs-récepteurs. 

Содержание Instant On AP11D

Страница 1: ...Single gang wiring box mount bracket 1 x Ethernet jumper cable 1 x Ethernet cable 2 x M2 5x 2mm Phillips head screw 2 x 6 32x1 5 Phillips head screw 1 x M2 5x6 5mm T8H Torx head security screw Hardwar...

Страница 2: ...D rear view LED Color State Meaning System No Lights Device has no power Blinking Green Device is starting Alternating Green Amber Device is ready for setup Solid Green Device is ready Solid Amber Dev...

Страница 3: ...a standard Powered Device PD from Power Sourcing Equipment PSE such as a midspan injector or a network infrastructure that supports PoE The E1 E3 ports located at the bottom of the access point are 1...

Страница 4: ...normal operation of the access point Power The AP11D access point supports up to 48V DC when using a proprietary Aruba power adapter This power adapter is available in the box if you buy the AP11D an...

Страница 5: ...points are placed below ducts to avoid RF disturbances RF interference sources include Microwave ovens and other 2 4 or 5 GHz objects such as cordless phones Cordless headset such as those used in ca...

Страница 6: ...f necessary 4 Removing the existing data wall plate if applicable 5 Remove any existing RJ45 connectors typically snap in or cut the UTP cable 6 Use the Ethernet cable to connect the E0 port to an RJ4...

Страница 7: ...1 GB17466 BS4662 and DIN49073 for Worldwide ANSI NEMA OS 1 and OS 2 for US Figure 7 Bracket to Wall Box US Figure 8 Bracket to Wall Box Worldwide 8 Insert the two included 6 32 x 1 5 Phillips head sc...

Страница 8: ...nstallation Connectivity The integrated LED on the access point can be used to verify that the access point access point is receiving power and initializing successfully see Table 1 Mobile Application...

Страница 9: ...r Canada it should be NRTL listed without an output rated 48VDC minimum 1 2A marked LPS and Class 2 and suitable for plugging into a standard power receptacle in the US and Canada RF Radiation Exposur...

Страница 10: ...r effective communication This device complies with Industry Canada s license exempt RSS regulations Operation of this device is subject to the following two conditions 1 this device may not cause int...

Страница 11: ...equirements of IEC 60601 1 3 Wipe with a dry cloth no additional maintenance required 4 No serviceable parts the unit must be sent back to the manufacturer for repair 5 No modifications are allowed wi...

Страница 12: ...be aceptar cualquier interferencia incluyendo la que pueda causar su operaci n no deseada Morocco Russia HPE Russia 125171 16 3 7 499 403 4248 7 499 403 4677 HPE Belarus 220030 36 1 375 17 392 28 20 H...

Страница 13: ...in compliance with Ukrainian Technical Regulation on Radio Equipment approved by resolution of the CABINET OF MINISTERS OF UKRAINE dated May 24 2017 No 355 The full text of the UA declaration of confo...

Страница 14: ...xpire three years following the date of the final distribution of this product version by Hewlett Packard Enterprise Company To obtain such source code send a check or money order in the amount of US...

Отзывы: