CAUTION:
• The Aruba 8360 switch is not compatible with fan trays from other Aruba hardware
platforms.
• After removing a fan tray, wait at least five seconds before inserting a replacement fan tray in
the same slot.
• Replace only one fan tray at a time. Removing more than one fan tray at a time compromises
system cooling, risks damage to the hardware, and can cause the switch to shut down
abruptly.
• If there are less than three fan trays installed, a two minute count down timer is triggered. If
three fan trays are not present before the countdown expires, the switch will automatically
power down for five minutes and then reboot. For this reason, it is not recommended to
remove a failed fan tray, until you have the replacement fan tray prepared.
Ensure that a replacement fan tray has the same airflow as other fan trays installed in the switch (Port-to-
Power or Power-to-Port).
To replace a fan tray:
Procedure
1. Identify the failed fan tray by its status LED. The fan tray LED will be FLASHING amber.
2. Remove the new fan tray from its packaging, being careful to not touch any of the circuitry on the board.
Chapter 5 Replacing components