Aruba 8360 Switch Series Installationand Getting Started Guide
Part Number: 5200-6930
Published: December 2020
Edition: 1
Страница 1: ...Aruba 8360 Switch Series Installation and Getting Started Guide Part Number 5200 6930 Published December 2020 Edition 1...
Страница 2: ...nterprise required for possession use or copying Consistent with FAR 12 211 and 12 212 Commercial Computer Software Computer Software Documentation and Technical Data for Commercial Items are licensed...
Страница 3: ...9 Power supply status LED 19 Load sharing 19 Redundancy 20 Hot swapping 20 Fan trays 20 Fan tray status LED 22 Switch features 22 Chapter 3 Installing the switch 23 Included parts 23 Parts not include...
Страница 4: ...it 54 Checking the switch LEDs 54 Checking console messages 54 Testing switch to device network communications 54 Testing end to end networking communications 55 Battery Statements 55 Chapter 7 Speci...
Страница 5: ...versal 4 post RM Kit J9583B Aruba 8360 16Y2C Prt2Pwr3F2PS Bdl JL702A Aruba 8360 24XF2C Pwr2Prt3F2PS Bdl JL711A Aruba X544 Universal 4 post Duct Kit JL716A Aruba 8360 16Y2C Pwr2Prt3F2PS Bdl JL703A Arub...
Страница 6: ...rs Fan trays System LEDs RJ serial console port Switch features Overview The Aruba 8360 Switch Series is a family of premium networking switches ideal for enterprise data centers network aggregation a...
Страница 7: ...of all 8360 switches 1 2 3 4 5 Table 1 Front of all 8360 switches Label Description 1 JL700A JL701A Aruba 8360 32Y4C 2 JL702A JL703A Aruba 8360 16Y2C 3 JL706A JL707A Aruba 8360 48XT4C Table Continued...
Страница 8: ...tion 1 SFP28 Ports1 2 QSFP28 port indicator LEDs 3 System LEDs Back Status Unit Identification Locator and Global Status 4 Reserved for future use 5 Out Of Band Management Link Activity LED 6 Out Of B...
Страница 9: ...nty or support are provided for the transceiver cable when used Network ports Table 3 Network ports Switch Model name SFP28 ports QSFP28 ports 10G Base t ports MACsec ports JL700A JL701A Aruba 8360 32...
Страница 10: ...a https support arubanetworks com ToolsResources tabid 76 DMXModule 514 Default aspx EntryId 7512 For more information on the console connection see Setup for initial configuration The console can be...
Страница 11: ...n 1 SFP28 ports1 2 QSFP port indicator LEDs 3 System LEDs Back Status Unit Identification Locator and Global Status 4 Reserved for future use 5 Out Of Band Management Link Activity LED 6 Out Of Band M...
Страница 12: ...er cable when used 2 Usr2 is reserved for future use Figure 4 Chassis and Port LEDs for the Aruba 8360 48XT4C JL706A JL707A 4 5 7 8 3 6 2 1 Table 5 Chassis and Port LED labels for the Aruba 8360 48XT4...
Страница 13: ...3 7 8 Table 6 Chassis and Port LED labels for the Aruba 8360 12C JL708A JL709A Label Description 1 QSFP port indicator LEDs 2 QSFP port indicator LEDs 3 QSFP port indicator LEDs 4 System LEDs Back Sta...
Страница 14: ...eries LEDs Function Switch Behavior LED State Meaning SFP28 port indicator RJ 45 port indicator Displays Link Activity or Mode information for the port Startup OFF OS CX No valid link SVOS Off Normal...
Страница 15: ...roughly proportional to the of full bandwidth utilization of the port Global Status Indicator Displays overall health status for the unit Startup Solid Green OS CX ArubaOS loading FLASH Green SVOS Se...
Страница 16: ...FLASH Blue 7 Blinks synchronously with Global Status LED Switch product label The switch product label is an Aruba Orange colored tab on the bottom right side of the switch front panel Pull the tab o...
Страница 17: ...Management ports Console port RJ 45 The RJ 45 console port is used for CLI serial port access NOTE RJ 45 and USB C console ports provide CLI serial port access The system will output to both consoles...
Страница 18: ...flow CAUTION System airflow direction Port to Power or Power to Port is configured automatically at system initialization and cannot be reconfigured by the user System airflow direction is determined...
Страница 19: ...EnterpriseProducts Brazil Statement Este equipamento deve ser conectado obrigatoriamente em tomada de rede de energia el trica que possua aterramento tr s pinos conforme a Norma NBR ABNT 5410 visando...
Страница 20: ...and or disabling misconfigured devices If adequate cooling cannot be maintained the switch will power off for five minutes before rebooting and assessing cooling capabilities CAUTION Fan trays and pow...
Страница 21: ...single fan tray while maintaining a safe operating temperature The switch may continue to operate with one failed fan tray If the switch reaches an overtemp condition the switch will shut down For bes...
Страница 22: ...isabled by default Dual power supplies Adding a second power supply provides redundant system power If one of the power supplies fails the second power supply continues to provide the power necessary...
Страница 23: ...t number or J number SKU are orderable through Aruba purchasing Two power cords required per switch Argentina 8121 0729 J9891A Israel 8121 1004 J9899A Australia New Zealand 8121 0837 J9883A Japan 8121...
Страница 24: ...itch 6 Mount the switch 7 Install transceivers optional 8 Connect the switch to a power source 9 Setup for initial configuration Installation precautions and guidelines To help avoid personal injury o...
Страница 25: ...ve a minimum of 6 inches 15 24 cm for cooling at the front and back of the switch For the air flow direction see the Fan trays section of this guide If a power supply must be removed and reinstalled w...
Страница 26: ...n the switch install power supplies in both slots before proceeding Aruba 8360 550W 100 240VAC JL600A Port to Power Airflow Aruba 8360 550W 100 240VAC JL712A Power to Port Airflow NOTE A red colored p...
Страница 27: ...in the switch Port to Power or Power to Port A red colored fan handle indicates a Port to Power air flow A blue colored fan handle indicates a Power to Port air flow 1 Remove the new fan tray from its...
Страница 28: ...switch operation For further detail see Chassis and Port LEDs on the front of the switch Power off the switch Prerequisites Remove the power cord from the switch and from the power source Mount the s...
Страница 29: ...5 millimeters behind the rack post 356 202 156 335 Aruba X414 1U Universal 4 Post RM Kit JL9583B 4 Post rack mountable with 4 Post rack mount kit in Port to Power or Power to Port configurations Aruba...
Страница 30: ...h in an equipment cabinet such as a server cabinet use the clips and screws that came with the cabinet in place of the 12 24 screws that are supplied with the two post rack mount kit Complete step 1 a...
Страница 31: ...er detail Figure 12 Attaching two post mounting brackets to the switch 2 1 2 1 WARNING For safe reliable installation only use the screws provided in the accessory kit to attach the mounting brackets...
Страница 32: ...r post rack mount option The Aruba 8360 switch can be mounted in four post racks and cabinets by using the Aruba X414 1U Universal 4 Post Rack Mount Kit JL9583B or the Aruba X544 Universal 4 Post Duct...
Страница 33: ...four clips Then proceed to step 2 1 Use a T20 drive screwdriver and attach the front post and rear post rack mount brackets to the switch with the included 8 mm M4 screws Figure 14 Attaching four pos...
Страница 34: ...lows cool air to be brought in from the aisle side of a rack for power to port airflow switches Without using the air duct kit warm air from the rack will be drawn into the switch chassis from the rac...
Страница 35: ...and 20 inch depth switches 4 Attach power cables to the switch and secure them to the power supply handles using cable ties or hook and loop fasteners not provided 5 Attach the console RJ cable to th...
Страница 36: ...1 2 8 Install the four post rack rail kit in the rack with the rear of the rails pointing toward the front cold aisle of the rack 36 Aruba 8360 Switch Series Installation and Getting Started Guide...
Страница 37: ...1 9 Install the switch with air duct kit into the rack rails and secure the switch and rack rails with two 2 10 32 screws Chapter 3 Installing the switch 37...
Страница 38: ...1 2 2 38 Aruba 8360 Switch Series Installation and Getting Started Guide...
Страница 39: ...o place When a transceiver is inserted the switch authenticates it This can take 1 3 seconds with the worst case being 5 seconds WARNING The Aruba transceivers are Class 1 laser devices Avoid direct e...
Страница 40: ...in conflict with the interface group configuration and will not be enabled Any interface in conflict with the current configuration will cause a fault event to be logged in the event log the interface...
Страница 41: ...mobile app can connect to the switch through the USB Bluetooth adapter For information about using the Aruba CX mobile app to configure the switch see the Fundamentals Guide for your switch and softw...
Страница 42: ...on the plug and pull the plug out of the port Connecting cables to transceivers If you have any transceivers installed in the switch the type of network connections you will need to use depends on the...
Страница 43: ...eboot the switch and reestablish the console session Connect to console port To connect a console to the switch follow these steps 1 Connect the PC or terminal to the switch s Console Port using a con...
Страница 44: ...ther end Figure 17 RJ 45 to DB 9 pinouts Table 14 Mapping of RJ 45 to DB 9 RJ 45 Signal freference from chassis DB 9 Signal reference from PC Reserved 1 8 CTS Reserved 2 6 DSR TXD 3 2 RXD Reserved 4 1...
Страница 45: ...nsert or remove a power supply while the power cord is connected Verify that cord has been disconnected from the power supply before installation or removal If the Aruba 8360 switch is configured with...
Страница 46: ...upply Slide it all the way in until the locking mechanism clicks into place 4 Connect the AC power cable to the new power supply s connector Replacing a fan tray The Aruba 8360 switch is equipped with...
Страница 47: ...timer is triggered If three fan trays are not present before the countdown expires the switch will automatically power down for five minutes and then reboot For this reason it is not recommended to re...
Страница 48: ...that its face plate is flush with the back face of the switch and the latch clicks If the switch is connected to an AC power source the fan tray should immediately start running Figure 19 Replacing a...
Страница 49: ...le wiring Improper network topologies It is important to make sure you have a valid network topology Common topology faults include excessive cable length and excessive repeater delays between end nod...
Страница 50: ...shing amber 2 On or flashing amber2 Flashing amber Flashing amber 3 Flashing green3 Flashing amber Flashing amber 4 On green Flashing amber Flashing amber Flashing amber 5 On green Flashing amber Flas...
Страница 51: ...authorized network reseller or use the electronic support services from Aruba to get assistance 3 The PSU with the LED on or flashing amber has faulted Try power cycling the PSU or removing and re in...
Страница 52: ...supported Aruba transceiver for SFP28 QSFP QSFP28 If using an unsupported SFP SFP transceiver confirm that unsupported transceiver mode is enabled For a list of supported transceivers see the ArubaOS...
Страница 53: ...the switch port configuration matches the configuration of the attached device For example if the switch port is configured as Full duplex the port on the attached device also MUST be configured as Fu...
Страница 54: ...rpreting the LED patterns Checking console messages Useful diagnostic messages may be displayed on the console screen when the switch is reset Connect a PC running a VT 100 terminal emulator program t...
Страница 55: ...n s il y a remplacement incorrect de la batterie Remplacer uniquement avec une batterie du m me type ou d un type quivalent recommand par le constructeur Mettre au rebut les batteries usag es conform...
Страница 56: ...44 25 cm 17 4 in 406 4 cm 16 0 in 4 4 cm 1 73 in 8 19 kg 18 05 lb Aruba 8360 16Y2C JL718A Aruba 8360 16Y2C PrtToPwr Configuration JL702A Aruba 8360 16Y2C PwrToPrt Configuration JL703A 44 25 cm 17 4 i...
Страница 57: ...in 8 01 kg 17 65 lb Aruba 8360 24XF2C JL722A Aruba 8360 24XF2C PrtToPwr Configuration JL701A Aruba 8360 24XF2C PwrToPrt Configuration JL711A 44 25 cm 17 4 406 4 cm 16 0 in 4 4 cm 1 73 in 8 07 kg 17 08...
Страница 58: ...Aruba 8360 48XT4C Prt2Pwr3F2PS Bdl JL706A Aruba 8360 12C Prt2Pwr3F2PS Bdl JL708A Aruba 8360 24XF2C Prt2Pwr3F2PS Bdl JL710A Aruba 8360 32Y4C Pwr2Prt3F2PS Bdl JL701A 550W Pwr2Prt JL712A Aruba 8360 16Y2C...
Страница 59: ...damaged or non recommended power cord with your switch Using such power cords voids the switch and power supply warranty It can also cause serious electrical problems including injury or death to per...
Страница 60: ...tude 10000 ft 3km 10000 ft 3km Max non operating altitude 15000 ft 4 5km 15000 ft 4 5km 1 Up to 5000 ft derate 1 C for every 1000 ft from 5000 ft to 10000 ft 2 Up to 5000 ft derate 1 C for every 1000...
Страница 61: ...tToPwr JL706A Sound Pressure LpAm Bystander 48 7 dB Sound Power LWAd 6 7 Bel Aruba 8360 48XT4C PwrToPrt JL707A Sound Pressure LpAm Bystander 47 6 dB Sound Power LWAd 6 5 Bel NOTE Acoustics measured in...
Страница 62: ...A EN55035 2017 CISPR35 EN 61000 3 2 2014 Class A EN 61000 3 3 2013 FCC CFR 47 Part 15 2010 Class A ICES 003 Class A VCCI Class A CNS 13438 Class A RoHS EN 50581 2012 IMPORTANT When selecting a fiber S...
Страница 63: ...g Direct Attach not an IEEE standard 10 Gig SR IEEE 802 3ae 10GBASE SR EN IEC 60825 Class 1 Laser Product Laser Klasse 1 10 Gig LR IEEE 802 3ae 10GBASE LR EN IEC 60825 Class 1 Laser Product Laser Klas...
Страница 64: ...2 3bj 100GBASE CR4 40 Gig DAC IEEE 802 3ba 40GBASE CR4 25 Gig SR IEEE 802 3by 25GBASE SR EN IEC 60825 Class 1 Laser Product Laser Klasse 1 25 Gig eSR not an IEEE standard EN IEC 60825 Class 1 Laser Pr...
Страница 65: ...cations Used for OOBM port 100 Mbps Operation Category 5 100 ohm UTP or STP cable complying with IEEE 802 3u 100BASE TX specifications Used for OOBM port Used for user ports on 48XT4C 1000 Mbps Operat...
Страница 66: ...end devices to the patch panels on your site The patch cables are frequently overlooked when testing cable and they must also comply with the cabling standards NOTE 10GBASE T cable requirements The Ca...
Страница 67: ...km 200 MHz km 400 MHz km 500 MHz km 2 220 meters 2 275 meters 2 500 meters 2 550 meters 1000BASE LX Single mode fiber N A 2 10 000 meters 1000BASE LH Single mode fiber N A 2 70 000 meters 10GBASE T Tw...
Страница 68: ...rs 2 150 meters 40GBASE eSR4 multimode fiber 1500 MHz km 3500 MHz km 2 330 meters 2 550 meters 40GBASE LR4 single mode fiber N A 2 10 000 meters 40GBASE ER4 single mode fiber N A 2 40 000 meters 40GBA...
Страница 69: ...on number if applicable Product name model or version and serial number Operating system name and version Firmware version Error messages Product specific reports and logs Add on products or component...
Страница 70: ...To view warranty information for your product go to https www arubanetworks com support services product warranties Regulatory information To view the regulatory information for your product view the...