![Aruba 7005 Series Скачать руководство пользователя страница 5](http://html1.mh-extra.com/html/aruba/7005-series/7005-series_installation-manual_2979179005.webp)
Aruba 7005 Series Controller
| Installation Guide
5
Kensington Security Slot
The Aruba 7005 controller is equipped with a Kensington security slot for additional security.
DC Power Socket
The AC-DC adapter kit with the following specification is used to power the Aruba 7005 controller:
12 VDC power interface
Center-positive 1.7/4.0 mm circular plug, 9.5 mm length
Installing the 7005 Controller
Using the Integrated Wall-Mounting Slots
The keyhole-shaped slots on the bottom of the controller can be used to attach the device upright (front
port facing downwards) to an indoor wall or shelf.
Since the ports are on the front of the device, make sure that you mount the controller is such a way that
there is a clear path to the Ethernet port, such as a predrilled hole in the mounting surface.
1. At the mounting location, install two screws on the wall or shelf, 120 mm apart. See
Figure 6
. If you are
attaching the device to drywall, it is recommended that you use appropriate wall anchors (not included).
Status
System status
Green (Solid)
Operational
Green (Blinking)
Device is loading software
Amber (Blinking)
Major Alarm
Amber (Solid)
Critical Alarm
Off
No power
Table 3
Power and Status LEDs
LED
Function
Indicator
Status
Service to all Aruba Networks, Inc. products should be performed by trained service personnel only.